Fast macromolecular proton fraction mapping from a single off‐resonance magnetization transfer measurement
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A new method was developed for fast quantitative mapping of the macromolecular proton fraction defined within the two‐pool model of magnetization transfer. The method utilizes a single image with off‐resonance saturation, a reference image for data normalization, and T1, B0, and B1 maps with the total acquisition time ∼10 min for whole‐brain imaging. Macromolecular proton fraction maps are reconstructed by iterative solution of the matrix pulsed magnetization transfer equation with constrained values of other model parameters. Theoretical error model describing the variance due to noise and the bias due to deviations of constrained parameters from their actual values was formulated based on error propagation rules. The method was validated by comparison with the conventional multiparameter multipoint fit of the pulsed magnetization transfer model based on data from two healthy subjects and two multiple sclerosis patients. It was demonstrated theoretically and experimentally that accuracy of the method depends on the offset frequency and flip angle of the saturation pulse, and optimal ranges of these parameters are 4–7 kHz and 600°–900°, respectively. At optimal sampling conditions, the single‐point method enables <10% relative macromolecular proton fraction errors. Comparison with the multiparameter fitting method revealed very good agreement with no significant bias and limits of agreement around ±0.7%. Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496
Cited by
Petrie, E. C., Cross, D. J., Yarnykh, V. L., Richards, T., Martin, N. M., Pagulayan, K., Hoff, D., Hart, K., Mayer, C., Tarabochia, M., et al. (2014) · Journal of Neurotrauma · doi:10.1089/neu.2013.2952 · Cited by 211
“During the second step, the pulsed magnetization transfer matrix equation 13,42 was iteratively solved by the Gauss-Newton method with B0 and B1 correction and standardized constraints for nonadjustable two-pool model parameters 14 to yield MPF maps.”
Self-citationAn interactive meta-analysis of MRI biomarkers of myelin
Mancini, M., Karakuzu, A., Cohen-Adad, J., Cercignani, M., Nichols, T. E., & Stikov, N. (2020) · eLife · doi:10.7554/elife.61523 · Cited by 168
Promise and pitfalls of g-ratio estimation with MRI
Campbell, J. S. W., Leppert, I. R., Narayanan, S., Boudreau, M., Duval, T., Cohen-Adad, J., Pike, G. B., & Stikov, N. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.038 · Cited by 129
Spatio-Temporal Patterns of Demyelination and Remyelination in the Cuprizone Mouse Model
Tagge, I., O’Connor, A., Chaudhary, P., Pollaro, J., Berlow, Y., Chalupsky, M., Bourdette, D., Woltjer, R., Johnson, M., & Rooney, W. (2016) · PLOS ONE · doi:10.1371/journal.pone.0152480 · Cited by 81
Metadata
- Authors
- Yarnykh, V. L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2011-12-21
- Volume
- 68
- Issue
- 1
- Pages
- 166-178
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2120654099
- Cited by
- 162
- References
- 1
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fast macromolecular proton fraction mapping from a single off‐resonance magnetization transfer measurement. https://app.cochat.ai/papers/10.1002/mrm.23224
- The paper
- Yarnykh, V. L. (2012). Fast macromolecular proton fraction mapping from a single off‐resonance magnetization transfer measurement. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.23224
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.