The DOI matches its Crossref record.
k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
Open accessAbstract
Dynamic images of natural objects exhibit significant correlations in k‐space and time. Thus, it is feasible to acquire only a reduced amount of data and recover the missing portion afterwards. This leads to an improved temporal resolution, or an improved spatial resolution for a given amount of acquisition. Based on this approach, two methods were developed to significantly improve the performance of dynamic imaging, named k‐t BLAST (Broad‐use Linear Acquisition Speed‐up Technique) and k‐t SENSE (SENSitivity Encoding) for use with a single or multiple receiver coils, respectively. Signal correlations were learned from a small set of training data and the missing data were recovered using all available information in a consistent and integral manner. The general theory of k‐t BLAST and k‐t SENSE is applicable to arbitrary k‐space trajectories, time‐varying coil sensitivities, and under‐ and overdetermined reconstruction problems. Examples from ungated cardiac imaging demonstrate a 4‐fold acceleration (voxel size 2.42 × 2.52 mm 2, 38.4 fps) with either one or six receiver coils. k‐t BLAST and k‐t SENSE are applicable to many areas, especially those exhibiting quasiperiodic motion, such as imaging of the heart, the lungs, the abdomen, and the brain under periodic stimulation. Magn Reson Med 50:1031–1042, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Markl, M., Frydrychowicz, A., Kozerke, S., Hope, M., & Wieben, O. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23632 · Cited by 788
Three-dimensional real-time in vivo magnetic particle imaging
Weizenecker, J., Gleich, B., Rahmer, J., Dahnke, H., & Borgert, J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/5/l01 · Cited by 651
Parallel magnetic resonance imaging
Larkman, D. J., & Nunes, R. G. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/7/r01 · Cited by 327
Zhao, B., Haldar, J. P., Christodoulou, A. G., & Liang, Z.-P. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2203921 · Cited by 295
Metadata
- Authors
- Tsao, J., Boesiger, P., & Pruessmann, K. P.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2003-10-24
- Volume
- 50
- Issue
- 5
- Pages
- 1031-1042
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2155268695
- Cited by
- 794
- References
- 0
- FWCI
- 17.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations. https://app.cochat.ai/papers/10.1002/mrm.10611
- The paper
- Tsao, J., Boesiger, P., & Pruessmann, K. P. (2003). k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10611
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.