Simultaneous acquisition of gradient‐echo and asymmetric spin‐echo for single‐shot z‐shim: Z‐SAGA
The DOI matches its Crossref record.
Abstract
This article describes the Z‐SAGA pulse sequence, a technique for recovering susceptibility losses in EPI images for neuroimaging applications. The pulse sequence is based on an asymmetric spin echo EPI sequence and acquires a gradient echo image and an asymmetric spin echo image in a single shot. For one of the images, a z‐shim gradient pulse is applied to compensate for susceptibility‐related field distortions. The two images are combined to form an image with reduced signal loss. This sequence is simple to implement and experimentally demonstrated to be effective for BOLD imaging. Magn Reson Med 51:212–216, 2004. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Felger, J. C., Li, Z., Haroon, E., Woolwine, B. J., Jung, M. Y., Hu, X., & Miller, A. H. (2016) · Molecular Psychiatry · doi:10.1038/mp.2015.168 · Cited by 620
Self-citationImaging human connectomes at the macroscale
Craddock, R. C., Jbabdi, S., Yan, C.-G., Vogelstein, J. T., Castellanos, F. X., Di Martino, A., Kelly, C., Heberlein, K., Colcombe, S., & Milham, M. P. (2013) · Nature Methods · doi:10.1038/nmeth.2482 · Cited by 419
Self-citationDisease state prediction from resting state functional connectivity
Craddock, R. C., Holtzheimer, P. E., Hu, X. P., & Mayberg, H. S. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22159 · Cited by 411
Self-citationDunlop, B. W., Rajendra, J. K., Craighead, W. E., Kelley, M. E., McGrath, C. L., Choi, K. S., Kinkead, B., Nemeroff, C. B., & Mayberg, H. S. (2017) · American Journal of Psychiatry · doi:10.1176/appi.ajp.2016.16050518 · Cited by 342
“Resting-state fMRI datawere acquired using a Z-SAGA sequence (46) to recover areas affected by susceptibility artifact, with the following parameters: 150 measurements; 30 axial slices; voxel resolution=3.”
Stevens, J. S., Jovanovic, T., Fani, N., Ely, T. D., Glover, E. M., Bradley, B., & Ressler, K. J. (2013) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2013.05.031 · Cited by 293
Metadata
- Authors
- Heberlein, K. A., & Hu, X.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2003-12-29
- Volume
- 51
- Issue
- 1
- Pages
- 212-216
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2160609978
- Cited by
- 60
- References
- 0
- FWCI
- 1.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous acquisition of gradient‐echo and asymmetric spin‐echo for single‐shot z‐shim: Z‐SAGA. https://app.cochat.ai/papers/10.1002/mrm.10680
- The paper
- Heberlein, K. A., & Hu, X. (2004). Simultaneous acquisition of gradient‐echo and asymmetric spin‐echo for single‐shot z‐shim: Z‐SAGA. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10680
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.