Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 209

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

SENSE‐DTI at 3 T

Open access
Jaermann, T., Crelier, G., Pruessmann, K.P., Golay, X., Netsch, T., van Muiswinkel, A.M.C, Mori, S., van Zijl, P.C.M., Valavanis, A., Kollias, S., Boesiger, P.·2004·Magnetic Resonance in Medicine

Abstract

While holding vast potential, diffusion tensor imaging (DTI) with single‐excitation protocols still faces serious challenges. Limited spatial resolution, susceptibility to magnetic field inhomogeneity, and low signal‐to‐noise ratio (SNR) may be considered the most prominent limitations. It is demonstrated that all of these shortcomings can be effectively mitigated by the transition to parallel imaging technology and high magnetic field strength. Using the sensitivity encoding (SENSE) technique at 3 T, brain DTI was performed in nine healthy volunteers. Despite enhanced field inhomogeneity, parallel acquisition permitted both controlling geometric distortions and enhancing spatial resolution up to 0.8 mm in‐plane. Heightened SNR requirements were met in part by high base sensitivity at 3 T. A further significant increase in SNR efficiency was accomplished by SENSE acquisition, exploiting enhanced encoding speed for echo time reduction. Based on the resulting image data, high‐resolution tensor mapping is demonstrated. Magn Reson Med 51:230–236, 2004. © 2004 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10707

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 209

Metadata

Authors
Jaermann, T., Crelier, G., Pruessmann, K. P., Golay, X., Netsch, T., van Muiswinkel, A. M. C., Mori, S., van Zijl, P. C. M., Valavanis, A., Kollias, S., & Boesiger, P.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2004-01-26
Volume
51
Issue
2
Pages
230-236
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2026229719
Cited by
209
References
2
FWCI
23.79
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.