The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
SENSE‐DTI at 3 T
Open accessAbstract
While holding vast potential, diffusion tensor imaging (DTI) with single‐excitation protocols still faces serious challenges. Limited spatial resolution, susceptibility to magnetic field inhomogeneity, and low signal‐to‐noise ratio (SNR) may be considered the most prominent limitations. It is demonstrated that all of these shortcomings can be effectively mitigated by the transition to parallel imaging technology and high magnetic field strength. Using the sensitivity encoding (SENSE) technique at 3 T, brain DTI was performed in nine healthy volunteers. Despite enhanced field inhomogeneity, parallel acquisition permitted both controlling geometric distortions and enhancing spatial resolution up to 0.8 mm in‐plane. Heightened SNR requirements were met in part by high base sensitivity at 3 T. A further significant increase in SNR efficiency was accomplished by SENSE acquisition, exploiting enhanced encoding speed for echo time reduction. Based on the resulting image data, high‐resolution tensor mapping is demonstrated. Magn Reson Med 51:230–236, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Diffusion Tensor Imaging and Axonal Tracking in the Human Brainstem
Stieltjes, B., Kaufmann, W. E., van Zijl, P. C. M., Fredericksen, K., Pearlson, G. D., Solaiyappan, M., & Mori, S. (2001) · NeuroImage · doi:10.1006/nimg.2001.0861 · Cited by 492
Self-citation
Cited by
Diffusion tensor imaging of the brain
Alexander, A. L., Lee, J. E., Lazar, M., & Field, A. S. (2007) · Neurotherapeutics · doi:10.1016/j.nurt.2007.05.011 · Cited by 2,747
Ageing and brain white matter structure in 3,513 UK Biobank participants
Cox, S. R., Ritchie, S. J., Tucker-Drob, E. M., Liewald, D. C., Hagenaars, S. P., Davies, G., Wardlaw, J. M., Gale, C. R., Bastin, M. E., & Deary, I. J. (2016) · Nature Communications · doi:10.1038/ncomms13629 · Cited by 487
Ultra-fast MRI of the human brain with simultaneous multi-slice imaging
Feinberg, D. A., & Setsompop, K. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2013.02.002 · Cited by 433
Hermoye, L., Saint-Martin, C., Cosnard, G., Lee, S.-K., Kim, J., Nassogne, M.-C., Menten, R., Clapuyt, P., Donohue, P. K., Hua, K., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.017 · Cited by 425
Self-citationBello, L., Gambini, A., Castellano, A., Carrabba, G., Acerbi, F., Fava, E., Giussani, C., Cadioli, M., Blasi, V., Casarotti, A., et al. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.08.031 · Cited by 416
Diffusion Tensor MR Imaging and Fiber Tractography: Technical Considerations
Mukherjee, P., Chung, S. W., Berman, J. I., Hess, C. P., & Henry, R. G. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1052 · Cited by 390
Q‐ball reconstruction of multimodal fiber orientations using the spherical harmonic basis
Hess, C. P., Mukherjee, P., Han, E. T., Xu, D., & Vigneron, D. B. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20931 · Cited by 366
Parallel magnetic resonance imaging
Larkman, D. J., & Nunes, R. G. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/7/r01 · Cited by 327
Sato, C., Naganawa, S., Nakamura, T., Kumada, H., Miura, S., Takizawa, O., & Ishigaki, T. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20251 · Cited by 323
Multi-contrast human neonatal brain atlas: Application to normal neonate development analysis
Oishi, K., Mori, S., Donohue, P. K., Ernst, T., Anderson, L., Buchthal, S., Faria, A., Jiang, H., Li, X., Miller, M. I., et al. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.051 · Cited by 306
Self-citationEluvathingal, T. J., Hasan, K. M., Kramer, L., Fletcher, J. M., & Ewing-Cobbs, L. (2007) · Cerebral Cortex · doi:10.1093/cercor/bhm003 · Cited by 288
Interslice leakage artifact reduction technique for simultaneous multislice acquisitions
Cauley, S. F., Polimeni, J. R., Bhat, H., Wald, L. L., & Setsompop, K. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24898 · Cited by 255
Chung, A. W., Seunarine, K. K., & Clark, C. A. (2016) · Human Brain Mapping · doi:10.1002/hbm.23328 · Cited by 63
Metadata
- Authors
- Jaermann, T., Crelier, G., Pruessmann, K. P., Golay, X., Netsch, T., van Muiswinkel, A. M. C., Mori, S., van Zijl, P. C. M., Valavanis, A., Kollias, S., & Boesiger, P.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-01-26
- Volume
- 51
- Issue
- 2
- Pages
- 230-236
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2026229719
- Cited by
- 209
- References
- 2
- FWCI
- 23.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.