Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 260

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Signal‐to‐noise ratio and absorbed power as functions of main magnetic field strength, and definition of “90°” RF pulse for the head in the birdcage coil

Collins, Christopher M., Smith, Michael B.·2001·Magnetic Resonance in Medicine

Abstract

Calculations of the RF magnetic (B1) field as a function of frequency between 64 and 345 MHz were performed for a head model in an idealized birdcage coil. Absorbed power (Pabs) and SNR were calculated at each frequency with three different methods of defining excitation pulse amplitude: maintaining 90° flip angle at the coil center (center α = π/2), maximizing FID amplitude (Max. AFID), and maximizing total signal amplitude in a reconstructed image (Max. Aimage). For center α = π/2 and Max. Aimage, SNR increases linearly with increasing field strength until 260 MHz, where it begins to increase at a greater rate. For these two methods, Pabs increases continually, but at a lower rate at higher field strengths. Above 215 MHz in MRI of the human head, the use of FID amplitude to set B1 excitation pulses may result in apparent decreases in SNR and power requirements with increasing static field strength. Magn Reson Med 45:684–691, 2001. © 2001 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1091

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 260

Metadata

Authors
Collins, C. M., & Smith, M. B.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2001-03-27
Volume
45
Issue
4
Pages
684-691
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2107122157
Cited by
260
References
1
FWCI
8.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Signal‐to‐noise ratio and absorbed power as functions of main magnetic field strength, and definition of “90°” RF pulse for the head in the birdcage coil. https://app.cochat.ai/papers/10.1002/mrm.1091
The paper
Collins, C. M., & Smith, M. B. (2001). Signal‐to‐noise ratio and absorbed power as functions of main magnetic field strength, and definition of “90°” RF pulse for the head in the birdcage coil. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1091

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.