The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Signal‐to‐noise ratio and absorbed power as functions of main magnetic field strength, and definition of “90°” RF pulse for the head in the birdcage coil
Abstract
Calculations of the RF magnetic (B1) field as a function of frequency between 64 and 345 MHz were performed for a head model in an idealized birdcage coil. Absorbed power (Pabs) and SNR were calculated at each frequency with three different methods of defining excitation pulse amplitude: maintaining 90° flip angle at the coil center (center α = π/2), maximizing FID amplitude (Max. AFID), and maximizing total signal amplitude in a reconstructed image (Max. Aimage). For center α = π/2 and Max. Aimage, SNR increases linearly with increasing field strength until 260 MHz, where it begins to increase at a greater rate. For these two methods, Pabs increases continually, but at a lower rate at higher field strengths. Above 215 MHz in MRI of the human head, the use of FID amplitude to set B1 excitation pulses may result in apparent decreases in SNR and power requirements with increasing static field strength. Magn Reson Med 45:684–691, 2001. © 2001 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Principles of Nuclear Magnetism
Abragam, A., & Hebel, L. C. (1961) · American Journal of Physics · doi:10.1119/1.1937646 · Cited by 15,792
Yee, K. (1966) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.1966.1138693 · Cited by 15,008
International Electrotechnical Commission
Buck, J. (2010) · Handbook of Transnational Economic Governance Regimes · doi:10.1163/ej.9789004163300.i-1081.494 · Cited by 2,742
The Finite Difference Time Domain Method for Electromagnetics
Kunz, K. S., & Luebbers, R. J. (2018) · CRC Press eBooks · doi:10.1201/9780203736708 · Cited by 2,518
Duck, F. A. (1990) · Cited by 2,461
Compilation of the Dielectric Properties of Body Tissues at RF and Microwave Frequencies.
Gabriel, C. (1996) · doi:10.21236/ada303903 · Cited by 2,097
The intrinsic signal-to-noise ratio in NMR imaging
Edelstein, W. A., Glover, G. H., Hardy, C. J., & Redington, R. W. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030413 · Cited by 758
Physical properties of tissue: F. A. Duck Harcourt Brace Jovanovich Ltd, London; 1990, 346 pp.
Bowker, P. (1991) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(91)90034-5 · Cited by 608
The principle of reciprocity in signal strength calculations?A mathematical guide
Hoult, D. I. (2000) · Concepts in Magnetic Resonance · doi:10.1002/1099-0534(2000)12:4<173::aid-cmr1>3.0.co;2-q · Cited by 550
Bottomley, P. A., & Andrew, E. R. (1978) · Physics in Medicine & Biology · doi:10.1088/0031-9155/23/4/006 · Cited by 407
Cited by
Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast
Gold, G. E., Han, E., Stainsby, J., Wright, G., Brittain, J., & Beaulieu, C. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.183.2.1830343 · Cited by 517
B1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil
Van de Moortele, P., Akgun, C., Adriany, G., Moeller, S., Ritter, J., Collins, C. M., Smith, M. B., Vaughan, J. T., & Uğurbil, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20708 · Cited by 468
Self-citationMetzger, G. J., Snyder, C., Akgun, C., Vaughan, T., Ugurbil, K., & Van de Moortele, P. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21476 · Cited by 319
Temperature and SAR calculations for a human head within volume and surface coils at 64 and 300 MHz
Collins, C. M., Liu, W., Wang, J., Gruetter, R., Vaughan, J. T., Ugurbil, K., & Smith, M. B. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20041 · Cited by 275
Self-citationWang, J., Zhang, Y., Wolf, R. L., Roc, A. C., Alsop, D. C., & Detre, J. A. (2005) · Radiology · doi:10.1148/radiol.2351031663 · Cited by 271
Van de Moortele, P.-F., Auerbach, E. J., Olman, C., Yacoub, E., Uğurbil, K., & Moeller, S. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.009 · Cited by 265
Analysis of wave behavior in lossy dielectric samples at high field
Yang, Q. X., Wang, J., Zhang, X., Collins, C. M., Smith, M. B., Liu, H., Zhu, X., Vaughan, J. T., Ugurbil, K., & Chen, W. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10137 · Cited by 255
Self-citationBernstein, M. A., Huston, J., & Ward, H. A. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20698 · Cited by 255
Metadata
- Authors
- Collins, C. M., & Smith, M. B.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2001-03-27
- Volume
- 45
- Issue
- 4
- Pages
- 684-691
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2107122157
- Cited by
- 260
- References
- 11
- FWCI
- 8.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.