The DOI matches its Crossref record.
Single‐voxel proton MRS of the human brain at 1.5T and 3.0T
Open accessAbstract
Single‐voxel proton spectra of the human brain were recorded in five subjects at both 1.5T and 3.0T using the STEAM pulse sequence. Data acquisition parameters were closely matched between the two field strengths. Spectra were recorded in the white matter of the centrum semiovale and in phantoms. Spectra were compared in terms of resolution and signal‐to‐noise ratio (SNR), and transverse relaxation times (T2) were estimated at both field strengths. Spectra at 3T demonstrated a 20% improvement in sensitivity compared to 1.5T at short echo times (TE = 20 msec), which was lower than the theoretical 100% improvement. Spectra at long echo times (TE = 272 msec) exhibited similar SNR at both field strengths. T2 relaxation times were almost twofold shorter at the higher field strength. Spectra in phantoms demonstrated significantly improved resolution at 3T compared to 1.5T, but resolution improvements in in vivo spectra were almost completely offset by increased linewidths at higher field. Magn Reson Med 45:765–769, 2001. © 2001 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tkáč, I., Öz, G., Adriany, G., Uğurbil, K., & Gruetter, R. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22086 · Cited by 364
Routine clinical brain MRI sequences for use at 3.0 Tesla
Lu, H., Nagae‐Poetscher, L. M., Golay, X., Lin, D., Pomper, M., & van Zijl, P. C. M. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20356 · Cited by 327
Whole-body MRI at high field: technical limits and clinical potential
Schick, F. (2005) · European Radiology · doi:10.1007/s00330-005-2678-0 · Cited by 314
Cardiac SSFP imaging at 3 Tesla
Schär, M., Kozerke, S., Fischer, S. E., & Boesiger, P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20024 · Cited by 307
Schubert, F., Gallinat, J., Seifert, F., & Rinneberg, H. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.11.014 · Cited by 282
Metadata
- Authors
- Barker, P. B., Hearshen, D. O., & Boska, M. D.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2001-04-16
- Volume
- 45
- Issue
- 5
- Pages
- 765-769
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2084689734
- Cited by
- 208
- References
- 0
- FWCI
- 8.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single‐voxel proton MRS of the human brain at 1.5T and 3.0T. https://app.cochat.ai/papers/10.1002/mrm.1104
- The paper
- Barker, P. B., Hearshen, D. O., & Boska, M. D. (2001). Single‐voxel proton MRS of the human brain at 1.5T and 3.0T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1104
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.