Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 208

The DOI matches its Crossref record.

Single‐voxel proton MRS of the human brain at 1.5T and 3.0T

Open access
Barker, Peter B., Hearshen, David O., Boska, Michael D.·2001·Magnetic Resonance in Medicine

Abstract

Single‐voxel proton spectra of the human brain were recorded in five subjects at both 1.5T and 3.0T using the STEAM pulse sequence. Data acquisition parameters were closely matched between the two field strengths. Spectra were recorded in the white matter of the centrum semiovale and in phantoms. Spectra were compared in terms of resolution and signal‐to‐noise ratio (SNR), and transverse relaxation times (T2) were estimated at both field strengths. Spectra at 3T demonstrated a 20% improvement in sensitivity compared to 1.5T at short echo times (TE = 20 msec), which was lower than the theoretical 100% improvement. Spectra at long echo times (TE = 272 msec) exhibited similar SNR at both field strengths. T2 relaxation times were almost twofold shorter at the higher field strength. Spectra in phantoms demonstrated significantly improved resolution at 3T compared to 1.5T, but resolution improvements in in vivo spectra were almost completely offset by increased linewidths at higher field. Magn Reson Med 45:765–769, 2001. © 2001 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1104

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Barker, P. B., Hearshen, D. O., & Boska, M. D.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2001-04-16
Volume
45
Issue
5
Pages
765-769
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2084689734
Cited by
208
References
0
FWCI
8.41
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.