The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Routine clinical brain MRI sequences for use at 3.0 Tesla
Open accessAbstract
Purpose: To establish image parameters for some routine clinical brain MRI pulse sequences at 3.0 T with the goal of maintaining, as much as possible, the well‐characterized 1.5‐T image contrast characteristics for daily clinical diagnosis, while benefiting from the increased signal to noise at higher field. Materials and Methods: A total of 10 healthy subjects were scanned on 1.5‐T and 3.0‐T systems for T 1 and T 2 relaxation time measurements of major gray and white matter structures. The relaxation times were subsequently used to determine 3.0‐T acquisition parameters for spin‐echo (SE), T 1‐weighted, fast spin echo (FSE) or turbo spin echo (TSE), T 2‐weighted, and fluid‐attenuated inversion recovery (FLAIR) pulse sequences that give image characteristics comparable to 1.5 T, to facilitate routine clinical diagnostics. Application of the routine clinical sequences was performed in 10 subjects, five normal subjects and five patients with various pathologies. Results: T 1 and T 2 relaxation times were, respectively, 14% to 30% longer and 12% to 19% shorter at 3.0 T when compared to the values at 1.5 T, depending on the region evaluated. When using appropriate parameters, routine clinical images acquired at 3.0 T showed similar image characteristics to those obtained at 1.5 T, but with higher signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR), which can be used to reduce the number of averages and scan times. Recommended imaging parameters for these sequences are provided. Conclusion: When parameters are adjusted for changes in relaxation rates, routine clinical scans at 3.0 T can provide similar image appearance as 1.5 T, but with superior image quality and/or increased speed. J. Magn. Reson. Imaging 2005;22:13–22. © 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
Bottomley, P. A., Foster, T. H., Argersinger, R. E., & Pfeifer, L. M. (1984) · Medical Physics · doi:10.1118/1.595535 · Cited by 1,192
What is the Correct Value for the Brain-Blood Partition Coefficient for Water?
Herscovitch, P., & Raichle, M. E. (1985) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1985.9 · Cited by 705
Luz, Z., & Meiboom, S. (1963) · The Journal of Chemical Physics · doi:10.1063/1.1734254 · Cited by 546
Experimental determination of the BOLD field strength dependence in vessels and tissue
Gati, J. S., Menon, R. S., Uǧurbil, K., & Rutt, B. K. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380220 · Cited by 523
Gelman, N., Gorell, J. M., Barker, P. B., Savage, R. M., Spickler, E. M., Windham, J. P., & Knight, R. A. (1999) · Radiology · doi:10.1148/radiology.210.3.r99fe41759 · Cited by 373
Gelman, N., Ewing, J. R., Gorell, J. M., Spickler, E. M., & Solomon, E. G. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200101)45:1<71::aid-mrm1011>3.0.co;2-2 · Cited by 268
Magnetic Resonance Imaging at 3.0 Tesla: Challenges and Advantages in Clinical Neurological Imaging
Frayne, R., Goodyear, B. G., Dickhoff, P., Lauzon, M. L., & Sevick, R. J. (2003) · Investigative Radiology · doi:10.1097/01.rli.0000073442.88269.c9 · Cited by 212
Single‐voxel proton MRS of the human brain at 1.5T and 3.0T
Barker, P. B., Hearshen, D. O., & Boska, M. D. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1104 · Cited by 208
Cited by
MP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high field
Marques, J. P., Kober, T., Krueger, G., van der Zwaag, W., Van de Moortele, P.-F., & Gruetter, R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.002 · Cited by 1,453
Cole, J. H. (2020) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2020.03.014 · Cited by 370
Quantitative evaluation of oxygenation in venous vessels using T2‐Relaxation‐Under‐Spin‐Tagging MRI
Lu, H., & Ge, Y. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21627 · Cited by 360
Self-citationHarris, A. D., Puts, N. A. J., & Edden, R. A. E. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24903 · Cited by 306
Multi-parametric neuroimaging reproducibility: A 3-T resource study
Landman, B. A., Huang, A. J., Gifford, A., Vikram, D. S., Lim, I. A. L., Farrell, J. A. D., Bogovic, J. A., Hua, J., Chen, M., Jarso, S., et al. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.11.047 · Cited by 299
Self-citation
Metadata
- Authors
- Lu, H., Nagae‐Poetscher, L. M., Golay, X., Lin, D., Pomper, M., & van Zijl, P. C. M.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2005-06-21
- Volume
- 22
- Issue
- 1
- Pages
- 13-22
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2102213632
- Cited by
- 327
- References
- 19
- FWCI
- 9.05
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Routine clinical brain MRI sequences for use at 3.0 Tesla. https://app.cochat.ai/papers/10.1002/jmri.20356
- The paper
- Lu, H., Nagae‐Poetscher, L. M., Golay, X., Lin, D., Pomper, M., & van Zijl, P. C. M. (2005). Routine clinical brain MRI sequences for use at 3.0 Tesla. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.20356
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.