High‐resolution fMRI using multislice partial k‐space GR‐EPI with cubic voxels
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The premises of this work are: 1) the limit of spatial resolution in fMRI is determined by anatomy of the microcirculation; 2) because of cortical gray matter tortuosity, fMRI experiments should (in principle) be carried out using cubic voxels; and 3) the noise in fMRI experiments is dominated by low‐frequency BOLD fluctuations that are a consequence of spontaneous neuronal events and are pixel‐wise dependent. A new model is proposed for fMRI contrast which predicts that the contrast‐to‐noise ratio (CNR) tends to be independent of voxel dimensions (in the absence of partial voluming of activated tissue), TE, and scanner bandwidth. These predictions have been tested at 3 T, and results support the model. Scatter plots of fMRI signal intensities and low‐frequency fluctuations for activated pixels in a finger‐tapping paradigm demonstrated a linear relationship between signal and noise that was independent of TE. The R2 value was about 0.9 across eight subjects studied. The CNR tended to be constant across pixels within a subject but varied across subjects: CNR = 3.2 ± 1.0. fMRI statistics at 20‐ and 40‐ms TE values were indistinguishable, and TE values as short as 10 ms were used successfully. Robust fMRI data were obtained across all subjects using 1 × 1 × 1 mm 3 cubic voxels with 10 contiguous slices, although 1.5 × 1.5 × 1.5 mm 3 was found to be optimum. Magn Reson Med 46:114–125, 2001. © 2001 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
Cited by
Accurate and robust brain image alignment using boundary-based registration
Greve, D. N., & Fischl, B. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.06.060 · Cited by 3,596
Representational similarity analysis-connecting the branches of systems neuroscience
Kriegeskorte, N. (2008) · Frontiers in Systems Neuroscience · doi:10.3389/neuro.06.004.2008 · Cited by 3,355
Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015710 · Cited by 1,296
“[43,44,45]) and these fluctuations form the basis of R-fMRI.”
BackgroundPattern Separation in the Human Hippocampal CA3 and Dentate Gyrus
Bakker, A., Kirwan, C. B., Miller, M., & Stark, C. E. L. (2008) · Science · doi:10.1126/science.1152882 · Cited by 1,052
The neural basis of the blood–oxygen–level–dependent functional magnetic resonance imaging signal
Logothetis, N. K. (2002) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.2002.1114 · Cited by 958
Metadata
- Authors
- Hyde, J. S., Biswal, B. B., & Jesmanowicz, A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2001-07
- Volume
- 46
- Issue
- 1
- Pages
- 114-125
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1998475172
- Cited by
- 143
- References
- 1
- FWCI
- 5.61
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High‐resolution fMRI using multislice partial k‐space GR‐EPI with cubic voxels. https://app.cochat.ai/papers/10.1002/mrm.1166
- The paper
- Hyde, J. S., Biswal, B. B., & Jesmanowicz, A. (2001). High‐resolution fMRI using multislice partial k‐space GR‐EPI with cubic voxels. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1166
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.