High‐resolution fMRI using multislice partial k‐space GR‐EPI with cubic voxels
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The premises of this work are: 1) the limit of spatial resolution in fMRI is determined by anatomy of the microcirculation; 2) because of cortical gray matter tortuosity, fMRI experiments should (in principle) be carried out using cubic voxels; and 3) the noise in fMRI experiments is dominated by low‐frequency BOLD fluctuations that are a consequence of spontaneous neuronal events and are pixel‐wise dependent. A new model is proposed for fMRI contrast which predicts that the contrast‐to‐noise ratio (CNR) tends to be independent of voxel dimensions (in the absence of partial voluming of activated tissue), TE, and scanner bandwidth. These predictions have been tested at 3 T, and results support the model. Scatter plots of fMRI signal intensities and low‐frequency fluctuations for activated pixels in a finger‐tapping paradigm demonstrated a linear relationship between signal and noise that was independent of TE. The R2 value was about 0.9 across eight subjects studied. The CNR tended to be constant across pixels within a subject but varied across subjects: CNR = 3.2 ± 1.0. fMRI statistics at 20‐ and 40‐ms TE values were indistinguishable, and TE values as short as 10 ms were used successfully. Robust fMRI data were obtained across all subjects using 1 × 1 × 1 mm 3 cubic voxels with 10 contiguous slices, although 1.5 × 1.5 × 1.5 mm 3 was found to be optimum. Magn Reson Med 46:114–125, 2001. © 2001 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
Cited by
Accurate and robust brain image alignment using boundary-based registration
Greve, D. N., & Fischl, B. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.06.060 · Cited by 3,596
Representational similarity analysis-connecting the branches of systems neuroscience
Kriegeskorte, N. (2008) · Frontiers in Systems Neuroscience · doi:10.3389/neuro.06.004.2008 · Cited by 3,355
Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015710 · Cited by 1,296
“[43,44,45]) and these fluctuations form the basis of R-fMRI.”
BackgroundPattern Separation in the Human Hippocampal CA3 and Dentate Gyrus
Bakker, A., Kirwan, C. B., Miller, M., & Stark, C. E. L. (2008) · Science · doi:10.1126/science.1152882 · Cited by 1,052
The neural basis of the blood–oxygen–level–dependent functional magnetic resonance imaging signal
Logothetis, N. K. (2002) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.2002.1114 · Cited by 958
Uğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
On the Definition of Signal-To-Noise Ratio and Contrast-To-Noise Ratio for fMRI Data
Welvaert, M., & Rosseel, Y. (2013) · PLoS ONE · doi:10.1371/journal.pone.0077089 · Cited by 493
Murphy, K., Bodurka, J., & Bandettini, P. A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.032 · Cited by 404
Arterial spin labeling perfusion fMRI with very low task frequency
Wang, J., Aguirre, G. K., Kimberg, D. Y., Roc, A. C., Li, L., & Detre, J. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10437 · Cited by 316
“Other evidence has suggested that drift effects may be influenced by spontaneous neuronal events and may be pixel-wise dependent (9).”
BackgroundSpin‐echo fMRI in humans using high spatial resolutions and high magnetic fields
Yacoub, E., Duong, T. Q., Van De Moortele, P., Lindquist, M., Adriany, G., Kim, S., Uğurbil, K., & Hu, X. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10433 · Cited by 308
CASSOT, F., LAUWERS, F., FOUARD, C., PROHASKA, S., & LAUWERS‐CANCES, V. (2006) · Microcirculation · doi:10.1080/10739680500383407 · Cited by 292
Lauwers, F., Cassot, F., Lauwers-Cances, V., Puwanarajah, P., & Duvernoy, H. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.09.024 · Cited by 274
Analyzing for information, not activation, to exploit high-resolution fMRI
Kriegeskorte, N., & Bandettini, P. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.022 · Cited by 270
The future of ultra-high field MRI and fMRI for study of the human brain
Duyn, J. H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.065 · Cited by 261
Resting‐state functional connectivity of the rat brain
Pawela, C. P., Biswal, B. B., Cho, Y. R., Kao, D. S., Li, R., Jones, S. R., Schulte, M. L., Matloub, H. S., Hudetz, A. G., & Hyde, J. S. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21524 · Cited by 201
Self-citationImaging at ultrahigh magnetic fields: History, challenges, and solutions
Uğurbil, K. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.007 · Cited by 173
“Some of these basal signal fluctuations are proportional to the signal magnitude (Hyde et al., 2001; Kruger and Glover, 2001; Yacoub et al., 2005); as such, they increase with field strength or, at a given field strength, with voxel volume (Triantafyllou et al.”
BackgroundUltra High-Resolution fMRI in Monkeys with Implanted RF Coils
Logothetis, N. K., Merkle, H., Augath, M., Trinath, T., & Uǧurbil, K. (2002) · Neuron · doi:10.1016/s0896-6273(02)00775-4 · Cited by 167
Lowering the thermal noise barrier in functional brain mapping with magnetic resonance imaging
Vizioli, L., Moeller, S., Dowdle, L., Akçakaya, M., De Martino, F., Yacoub, E., & Uğurbil, K. (2021) · Nature Communications · doi:10.1038/s41467-021-25431-8 · Cited by 165
Bodurka, J., Ye, F., Petridou, N., Murphy, K., & Bandettini, P. A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.039 · Cited by 158
Bellgowan, P. S. F., Bandettini, P. A., van Gelderen, P., Martin, A., & Bodurka, J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.042 · Cited by 84
“The paradox of higher TSNR but lower CNR in thicker compared to thinner slices can be interpreted as a significant reduction in noise for thinner slices accomplished by decreasing the partial volume effect (Hyde et al., 2001).”
Background
Metadata
- Authors
- Hyde, J. S., Biswal, B. B., & Jesmanowicz, A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2001-07
- Volume
- 46
- Issue
- 1
- Pages
- 114-125
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1998475172
- Cited by
- 143
- References
- 1
- FWCI
- 5.61
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.