CoChat

IMPACT: Image‐based physiological artifacts estimation and correction technique for functional MRI

Open access
Chuang, Kai‐Hsiang, Chen, Jyh‐Horng · 2001 · Magnetic Resonance in Medicine
Cited by 72

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Functional MRI (fMRI) signal variation induced by respiratory and cardiac motion affects the activation signal and limits the accuracy of analysis. Current physiological motion correction methods require either synchronization with external monitoring of respiration and heartbeat, specialized pulse sequence design, or k‐space data. The IMage‐based Physiological Artifacts estimation and Correction Technique (IMPACT), which is free from these constraints, is described. When images are acquired fast enough to sample physiological motion without aliasing, respiratory and cardiac signals can be directly estimated from magnitude images. Physiological artifacts are removed by reordering images according to the estimated respiratory and cardiac phases and then subtracting the Fourier‐fitted variation from magnitude images. Compared with the k‐space–based method, this method can efficiently and effectively reduce the overall signal fluctuation in the brain and increase the activated area. With this new technique, physiological artifacts can be reduced using traditional fMRI pulse sequences, and existing data can be corrected and reanalyzed without additional experiments. Magn Reson Med 46:344–353, 2001. © 2001 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1197

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 72

Metadata

Authors
Chuang, K., & Chen, J.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2001-07-24
Volume
46
Issue
2
Pages
344-353
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2158477074
Cited by
72
References
1
FWCI
2.52
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.