IMPACT: Image‐based physiological artifacts estimation and correction technique for functional MRI
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Functional MRI (fMRI) signal variation induced by respiratory and cardiac motion affects the activation signal and limits the accuracy of analysis. Current physiological motion correction methods require either synchronization with external monitoring of respiration and heartbeat, specialized pulse sequence design, or k‐space data. The IMage‐based Physiological Artifacts estimation and Correction Technique (IMPACT), which is free from these constraints, is described. When images are acquired fast enough to sample physiological motion without aliasing, respiratory and cardiac signals can be directly estimated from magnitude images. Physiological artifacts are removed by reordering images according to the estimated respiratory and cardiac phases and then subtracting the Fourier‐fitted variation from magnitude images. Compared with the k‐space–based method, this method can efficiently and effectively reduce the overall signal fluctuation in the brain and increase the activated area. With this new technique, physiological artifacts can be reduced using traditional fMRI pulse sequences, and existing data can be corrected and reanalyzed without additional experiments. Magn Reson Med 46:344–353, 2001. © 2001 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Cited by
Murphy, K., Birn, R. M., Handwerker, D. A., Jones, T. B., & Bandettini, P. A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.09.036 · Cited by 2,387
“Other techniques have been developed that do not require physiological recordings (Beall and Lowe, 2007; Chuang and Chen, 2001; Perlbarg et al., 2007).”
Van Dijk, K. R. A., Hedden, T., Venkataraman, A., Evans, K. C., Lazar, S. W., & Buckner, R. L. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00783.2009 · Cited by 1,844
Birn, R. M., Diamond, J. B., Smith, M. A., & Bandettini, P. A. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.048 · Cited by 1,358
Very Slow Activity Fluctuations in Monkey Visual Cortex: Implications for Functional Brain Imaging
Leopold, D. A. (2003) · Cerebral Cortex · doi:10.1093/cercor/13.4.422 · Cited by 675
Resting-state fMRI confounds and cleanup
Murphy, K., Birn, R. M., & Bandettini, P. A. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.001 · Cited by 666
“3 Hz) frequencieswas first demonstratedwith such a technique dubbed IMPACT — Image-based Physiological Artifacts Estimation and Correction Technique (Chuang and Chen, 2001).”
InfluentialMethods for cleaning the BOLD fMRI signal
Caballero-Gaudes, C., & Reynolds, R. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.018 · Cited by 542
Shmueli, K., van Gelderen, P., de Zwart, J. A., Horovitz, S. G., Fukunaga, M., Jansma, J. M., & Duyn, J. H. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.07.037 · Cited by 541
The role of physiological noise in resting-state functional connectivity
Birn, R. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.016 · Cited by 359
Birn, R. M., Murphy, K., & Bandettini, P. A. (2008) · Human Brain Mapping · doi:10.1002/hbm.20577 · Cited by 283
Noise contributions to the fMRI signal: An overview
Liu, T. T. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.09.008 · Cited by 275
Evaluating fMRI preprocessing pipelines
Strother, S. C. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1607667 · Cited by 169
“Many other approaches have been proposed for suppressing the cardiac and respiratory noise, and they fall into four groups: two based on k-space/image measurements with application of the estimated physiological correction variables in k-space [62], [63] or the reconstructed images [64], [65] and two using external mo…”
BackgroundMethodPhysiological noise reduction for arterial spin labeling functional MRI
Restom, K., Behzadi, Y., & Liu, T. T. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.026 · Cited by 101
“rigorous metric of statistical significance is desired, we have included correlation coefficients in our presentation to facilitate a qualitative comparison with a number of previous investigations that have used correlation coefficients to assess the impact of physiological noise reduction in BOLD experiments (Hu et…”
Method
Metadata
- Authors
- Chuang, K., & Chen, J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2001-07-24
- Volume
- 46
- Issue
- 2
- Pages
- 344-353
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2158477074
- Cited by
- 72
- References
- 1
- FWCI
- 2.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.