The DOI matches its Crossref record.
High‐resolution intracranial and cervical MRA at 3.0T: Technical considerations and initial experience
Open accessAbstract
Initial experience with intracranial and cervical MRA at 3.0T is reported. Phantom measurements (corrected for relaxation effects) show S/N (3.0T) = 2.14 ± 0.08 × S/N (1.5T) in identical‐geometry head coils. A 3.0T 3DTOF intracranial imaging protocol with higher‐order autoshimming was developed and compared to 1.5T 3DTOF in 12 patients with aneurysms. A comparison by two radiologists showed the 3.0T to be significantly better (P < 0.001) for visualization of the aneurysms. The feasibility of cervical and intracranial contrast enhanced MR angiography (CEMRA) at 3.0T is also examined. The relaxivity of the gadolinium contrast agent decreases by only about 4–7% when the field strength is increased from 1.5 to 3.0T. Cervical 3.0T CEMRA was obtained in eight patients, two of whom had 1.5T studies available for direct comparison. Image comparison suggests 3.0T to be a favorable field strength for cervical CEMRA. Voxel volumes of 0.62–0.73 mm 3 (not including zero‐filling) were readily achieved at 3.0T with the use of a single‐channel transmit‐receive head or cervical coil, a 25 mL bolus of gadoteridol, and a 3D pulse sequence with a 66% sampling efficiency. This spatial resolution allowed visualization of intracranial aneurysms, carotid dissections, and atherosclerotic disease including ulcerations. Potential drawbacks of 3.0T MRA are increased SAR and T dephasing compared to 1.5T. Image comparison suggests signal loss due to T dephasing will not be substantially more problematic than at 1.5T. The dependence of RF power deposition on TR for CEMRA is calculated and discussed. Magn Reson Med 46:955–962, 2001. © 2001 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla
Lu, H., Clingman, C., Golay, X., & van Zijl, P. C. M. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20178 · Cited by 685
Miyazaki, M., & Lee, V. S. (2008) · Radiology · doi:10.1148/radiol.2481071497 · Cited by 407
Routine clinical brain MRI sequences for use at 3.0 Tesla
Lu, H., Nagae‐Poetscher, L. M., Golay, X., Lin, D., Pomper, M., & van Zijl, P. C. M. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20356 · Cited by 327
Cardiac SSFP imaging at 3 Tesla
Schär, M., Kozerke, S., Fischer, S. E., & Boesiger, P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20024 · Cited by 307
Bernstein, M. A., Huston, J., & Ward, H. A. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20698 · Cited by 255
Self-citation
Metadata
- Authors
- Bernstein, M. A., Huston, J., Lin, C., Gibbs, G. F., & Felmlee, J. P.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2001-10-18
- Volume
- 46
- Issue
- 5
- Pages
- 955-962
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1998221749
- Cited by
- 206
- References
- 0
- FWCI
- 10.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High‐resolution intracranial and cervical MRA at 3.0T: Technical considerations and initial experience. https://app.cochat.ai/papers/10.1002/mrm.1282
- The paper
- Bernstein, M. A., Huston, J., Lin, C., Gibbs, G. F., & Felmlee, J. P. (2001). High‐resolution intracranial and cervical MRA at 3.0T: Technical considerations and initial experience. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1282
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.