In vivo proton spectroscopy in presence of eddy currents
Abstract
Spatially localized methods in spectroscopy often operate with magnetic field gradients for volume selection. The eddy currents induced by these gradients produce time‐dependent shifts of the resonance frequency in the selected volume, which results in a distortion of the spectrum after Fourier transformation. In whole‐body systems the complete compensation of eddy currents is a difficult procedure. To avoid this, a correction method is proposed for proton spectroscopy, which uses the signal of prominent water protons as a reference for the water‐suppressed signal. The correction is performed in the time domain, dividing the water‐suppressed signal by the phase factor of the water signal for each data point. The corrected spectra have a good resolution as shown by phantom measurements and brain and muscle spectra of volunteers. © 1990 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frahm, J., Bruhn, H., Gyngell, M. L., Merboldt, K. D., Hänicke, W., & Sauter, R. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910090110 · Cited by 709
Ordidge, R. J., & Cresshull, I. D. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90228-3 · Cited by 126
Whole-body MR imaging and spectroscopy with a 4-T system.
Barfuss, H., Fischer, H., Hentschel, D., et al. (1988) · Radiology · doi:10.1148/radiology.169.3.3187004 · Cited by 77
In vivo 1H spectroscopic studies of human gastrocnemius muscle at 1.5 T
Narayana, P. A., Hazle, J. D., Jackson, E. F., Fotedar, L. K., & Kulkarni, M. V. (1988) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(88)90121-x · Cited by 22
Cited by
Estimation of metabolite concentrations from localized in vivo proton NMR spectra
Provencher, S. W. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300604 · Cited by 3,655
Howe, F. A., Barton, S. J., Cudlip, S. A., Stubbs, M., Saunders, D. E., Murphy, M., Wilkins, P., Opstad, K. S., Doyle, V. L., McLean, M. A., et al. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10367 · Cited by 539
Use of tissue water as a concentration reference for proton spectroscopic imaging
Gasparovic, C., Song, T., Devier, D., Bockholt, H. J., Caprihan, A., Mullins, P. G., Posse, S., Jung, R. E., & Morrison, L. A. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20901 · Cited by 509
Methodological consensus on clinical proton MRS of the brain: Review and recommendations
Wilson, M., Andronesi, O., Barker, P. B., Bartha, R., Bizzi, A., Bolan, P. J., Brindle, K. M., Choi, I., Cudalbu, C., Dydak, U., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27742 · Cited by 470
Regional metabolite concentrations in human brain as determined by quantitative localized proton MRS
Pouwels, P. J. W., & Frahm, J. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390110 · Cited by 465
Metadata
- Authors
- Klose, U.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1990-04
- Volume
- 14
- Issue
- 1
- Pages
- 26-30
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2061405560
- Cited by
- 580
- References
- 4
- FWCI
- 6.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.