The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Three‐dimensional magnetization‐prepared rapid gradient‐echo imaging (3D MP RAGE)
Abstract
A new three‐dimensional imaging technique which is applicable for 3D MR imaging throughout the body is introduced. In our preliminary investigations we have acquired high‐quality 3D image sets of the abdomen showing minimal respiratory artifacts in just over 7 min (voxel size 2.7 × 2.7 × 2.7 mm 3), and 3D image sets of the head showing excellent gray/white contrast in less than 6 min (voxel size 1.0 × 2.0 × 1.4 mm 3). © 1990 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
FLASH imaging: Rapid NMR imaging using low flip-angle pulses
Haase, A., Frahm, J., Matthaei, D., Hänicke, W., & Merboldt, K.-D. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.09.021 · Cited by 1,153
FLASH imaging. Rapid NMR imaging using low flip-angle pulses
Haase, A., Frahm, J., Matthaei, D., Hanicke, W., & Merboldt, K.-D. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90433-6 · Cited by 826
Snapshot flash mri. applications to t1, t2, and chemical‐shift imaging
Haase, A. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130109 · Cited by 693
Inversion Recovery Snapshot FLASH MR Imaging
Haase, A., Matthaei, D., Bartkowski, R., Dühmke, E., & Leibfritz, D. (1989) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198911000-00016 · Cited by 157
Cited by
The minimal preprocessing pipelines for the Human Connectome Project
Glasser, M. F., Sotiropoulos, S. N., Wilson, J. A., Coalson, T. S., Fischl, B., Andersson, J. L., Xu, J., Jbabdi, S., Webster, M., Polimeni, J. R., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.127 · Cited by 5,253
Marcus, D. S., Wang, T. H., Parker, J., Csernansky, J. G., Morris, J. C., & Buckner, R. L. (2007) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2007.19.9.1498 · Cited by 2,163
A Core System for the Implementation of Task Sets
Dosenbach, N. U. F., Visscher, K. M., Palmer, E. D., Miezin, F. M., Wenger, K. K., Kang, H. C., Burgund, E. D., Grimes, A. L., Schlaggar, B. L., & Petersen, S. E. (2006) · Neuron · doi:10.1016/j.neuron.2006.04.031 · Cited by 1,772
“A T1-weighted sagittal MPRAGE structural image was obtained (TE = 4 ms; MR frame = 9.7 ms; TI = 300 ms; flip angle = 12º; 128 slices with 1.25 3 1 3 1 mm voxels; Mugler and Brookeman, 1990).”
MethodInfluentialDifferential Effects of Early Hippocampal Pathology on Episodic and Semantic Memory
Vargha-Khadem, F., Gadian, D. G., Watkins, K. E., Connelly, A., Van Paesschen, W., & Mishkin, M. (1997) · Science · doi:10.1126/science.277.5324.376 · Cited by 1,746
Image processing and Quality Control for the first 10,000 brain imaging datasets from UK Biobank
Alfaro-Almagro, F., Jenkinson, M., Bangerter, N. K., Andersson, J. L. R., Griffanti, L., Douaud, G., Sotiropoulos, S. N., Jbabdi, S., Hernandez-Fernandez, M., Vallee, E., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.10.034 · Cited by 1,557
Metadata
- Authors
- Mugler, J. P., & Brookeman, J. R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1990-07
- Volume
- 15
- Issue
- 1
- Pages
- 152-157
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2000574253
- Cited by
- 1,265
- References
- 4
- FWCI
- 13.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.