Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 173

The DOI matches its Crossref record.

Motion‐insensitive, steady‐state free precession imaging

Zur, Y., Wood, M. L., Neuringer, L. J.·1990·Magnetic Resonance in Medicine

Abstract

Steady‐state free precession (SSFP) pulse sequences employing gradient reversal echoes and short repetition time (TR) between successive rf excitation pulses offer high signal‐to‐noise ratio per unit time. However, SSFP sequences are very sensitive to motion. A new SSFP method is presented which avoids the image artifacts and loss of signal intensity due to motion. The pulse sequence is designed so that the time integral of each of the three gradients is zero over each TR time interval. The signal then consists of numerous echoes which are superimposed. These echoes are isolated by combining the data from N different scans. In each scan a specific phase shift is added during every TR interval. Each of these N isolated echoes produces a motion‐insensitive, artifact‐free image. Because all the echoes are sampled simultaneously, the signal‐to‐noise ratio per unit time in this SSFP method is higher than in existing SSFP techniques which sample only one echo at a time. The new method was implemented and used to produce both two‐ and three‐dimensional images of the head and cervical spin of a human patient. In these images the high signal intensity of cerebrospinal fluid is preserved regardless of its motion. Further work is required to evaluate the imaging parameters (TR, TE, rf tip angle) so as to give optimal tissue contrast for the various echoes. © 1990 Academic Press, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910160311

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 173

Metadata

Authors
Zur, Y., Wood, M. L., & Neuringer, L. J.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1990-12
Volume
16
Issue
3
Pages
444-459
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1968357624
Cited by
173
References
0
FWCI
2.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Motion‐insensitive, steady‐state free precession imaging. https://app.cochat.ai/papers/10.1002/mrm.1910160311
The paper
Zur, Y., Wood, M. L., & Neuringer, L. J. (1990). Motion‐insensitive, steady‐state free precession imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910160311

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.