Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 472

The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.

Gleaning multicomponent T1 and T2 information from steady‐state imaging data

Deoni, Sean C.L., Rutt, Brian K., Arun, Tarunya, Pierpaoli, Carlo, Jones, Derek K.·2008·Magnetic Resonance in Medicine

Abstract

The driven‐equilibrium single‐pulse observation of T1 (DESPOT1) and T2 (DESPOT2) are rapid, accurate, and precise methods for voxelwise determination of the longitudinal and transverse relaxation times. A limitation of the methods, however, is the inherent assumption of single‐component relaxation. In a variety of biological tissues, in particular human white matter (WM) and gray matter (GM), the relaxation has been shown to be more completely characterized by a summation of two or more relaxation components, or species, each believed to be associated with unique microanatomical domains or water pools. Unfortunately, characterization of these components on a voxelwise, whole‐brain basis has traditionally been hindered by impractical acquisition times. In this work we extend the conventional DESPOT1 and DESPOT2 approaches to include multicomponent relaxation analysis. Following numerical analysis of the new technique, renamed multicomponent driven equilibrium single pulse observation of T1/T2 (mcDESPOT), whole‐brain multicomponent T1 and T2 quantification is demonstrated in vivo with clinically realistic times of between 16 and 30 min. Results obtained from four healthy individuals and two primary progressive multiple sclerosis (MS) patients demonstrate the future potential of the approach for identifying and assessing tissue changes associated with several neurodegenerative conditions, in particular those associated with WM. Magn Reson Med 60:1372–1387, 2008. © 2008 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.21704

Cites

48 of 48 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 48 references

Cited by

See all 472

Metadata

Authors
Deoni, S. C. L., Rutt, B. K., Arun, T., Pierpaoli, C., & Jones, D. K.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2008-11-24
Volume
60
Issue
6
Pages
1372-1387
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2117245594
Cited by
472
References
48
FWCI
7.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Gleaning multicomponent T1 and T2 information from steady‐state imaging data. https://app.cochat.ai/papers/10.1002/mrm.21704
The paper
Deoni, S. C. L., Rutt, B. K., Arun, T., Pierpaoli, C., & Jones, D. K. (2008). Gleaning multicomponent T1 and T2 information from steady‐state imaging data. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21704

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.