The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
GRASE (Gradient‐and Spin‐Echo) imaging: A novel fast MRI technique
Abstract
A fast multi‐section MR imaging technique is described. Gradient‐ and spin‐echo (GRASE) imaging utilizes the speed advantages of gradient refocusing while overcoming the image artifacts arising from static field inhomogeneity and chemical shift. Image contrast is determined by the T2 contrast in the Hahn spin echoes. A novel k‐space trajectory temporally modulates signals and demodulates artifacts. © 1991 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Halving MR imaging time by conjugation: demonstration at 3.5 kG.
Feinberg, D. A., Hale, J. D., Watts, J. C., Kaufman, L., & Mark, A. (1986) · Radiology · doi:10.1148/radiology.161.2.3763926 · Cited by 259
Self-citationInstant images of the human heart using a new, whole-body MR imaging system
Rzedzian, R. R., & Pykett, I. L. (1987) · American Journal of Roentgenology · doi:10.2214/ajr.149.2.245 · Cited by 139
Echo‐planar imaging with asymmetric gradient modulation and inner‐volume excitation
Feinberg, D. A., Turner, R., Jakab, P. D., et al. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130116 · Cited by 86
Self-citation
Cited by
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Multicoil Dixon chemical species separation with an iterative least‐squares estimation method
Reeder, S. B., Wen, Z., Yu, H., Pineda, A. R., Gold, G. E., Markl, M., & Pelc, N. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10675 · Cited by 508
Low‐field MRI: An MR physics perspective
Marques, J. P., Simonis, F. F. J., & Webb, A. G. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26637 · Cited by 386
A neuroradiologist’s guide to arterial spin labeling MRI in clinical practice
Grade, M., Hernandez Tamames, J. A., Pizzini, F. B., Achten, E., Golay, X., & Smits, M. (2015) · Neuroradiology · doi:10.1007/s00234-015-1571-z · Cited by 298
MRI‐based myelin water imaging: A technical review
Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25198 · Cited by 285
Metadata
- Authors
- Oshio, K., & Feinberg, D. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1991-08
- Volume
- 20
- Issue
- 2
- Pages
- 344-349
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2168110165
- Cited by
- 340
- References
- 3
- FWCI
- 7.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.