The DOI matches its Crossref record.
Reduction of susceptibility artifact in gradient‐echo imaging
Abstract
A new technique with which susceptibility artifact in gradient‐echo imaging can be reduced substantially by use of a tailored RF pulse is described. The proposed technique can ideally be applied to the case where high local magnetic field inhomogeneity is dominated by the susceptibility. The signal loss and void phenomena due to susceptibility in a voxel are studied and a correction method is also proposed. The description of the tailored RF pulse and its proposed application are given and experimental results obtained using a human volunteer with a 2.0‐T KAIS NMR system are presented. © 1992 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Overview of Functional Magnetic Resonance Imaging
Glover, G. H. (2011) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2010.11.001 · Cited by 1,024
“Another problem is signal dropout and/or spatial distortion in frontal orbital and lateral parietal regions, caused by the difference of approximately 9 ppm in magnetic susceptibility at interfaces between air and brain tissue.(42) This situation can result in erroneous lack of BOLD signal in ventral, temporal, and pr…”
BackgroundOptimized EPI for fMRI studies of the orbitofrontal cortex
Deichmann, R., Gottfried, J. A., Hutton, C., & Turner, R. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00073-9 · Cited by 821
Ojemann, J. G., Akbudak, E., Snyder, A. Z., McKinstry, R. C., Raichle, M. E., & Conturo, T. E. (1997) · NeuroImage · doi:10.1006/nimg.1997.0289 · Cited by 694
Spiral‐in/out BOLD fMRI for increased SNR and reduced susceptibility artifacts
Glover, G. H., & Law, C. S. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1222 · Cited by 599
Lee, M.-J., Kim, S., Lee, S.-A., Song, H.-T., Huh, Y.-M., Kim, D.-H., Han, S. H., & Suh, J.-S. (2007) · RadioGraphics · doi:10.1148/rg.273065087 · Cited by 513
Weiskopf, N., Hutton, C., Josephs, O., & Deichmann, R. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.07.029 · Cited by 475
Gelman, N., Gorell, J. M., Barker, P. B., Savage, R. M., Spickler, E. M., Windham, J. P., & Knight, R. A. (1999) · Radiology · doi:10.1148/radiology.210.3.r99fe41759 · Cited by 373
Theory and application of static field inhomogeneity effects in gradient‐echo imaging
Reichenbach, J. R., Venkatesan, R., Yablonskiy, D. A., Thompson, M. R., Lai, S., & Haacke, E. M. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070203 · Cited by 285
Compensation of susceptibility-induced bold sensitivity losses in echo-planar fMRI imaging
Deichmann, R., Josephs, O., Hutton, C., Corfield, D. R., & Turner, R. (2002) · NeuroImage · doi:10.1006/nimg.2001.0985 · Cited by 253
Bellgowan, P. S. F., Bandettini, P. A., van Gelderen, P., Martin, A., & Bodurka, J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.042 · Cited by 84
Metadata
- Authors
- Cho, Z. H., & Ro, Y. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1992-01
- Volume
- 23
- Issue
- 1
- Pages
- 193-200
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2038363842
- Cited by
- 165
- References
- 0
- FWCI
- 3.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.