The DOI matches its Crossref record.
Deblurring for non‐2D fourier transform magnetic resonance imaging
Abstract
For several non‐2D Fourier transform imaging methods, off‐resonant reconstruction does not just cause geometric distortion, but changes the shape of the point spread function and causes blurring. This effect is well known for projection reconstruction and spiral k‐space scanning sequences. We introduce here a method that automatically removes blur introduced by magnetic field inhomogeneity and susceptibility without using a resonant frequency map, making these imaging methods more useful. In this method, the raw data are modulated to several different frequencies and reconstructed to create a series of base images. Determination of degree of blur is done by calculating a focusing measure for each point in each base image and a composite image is then constructed using only the unblurred regions from each base image. This method has been successfully applied to phantom and in vivo images using projection‐reconstruction and spiral‐scan sequences. © 1992 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Poldrack, R. A., Wagner, A. D., Prull, M. W., Desmond, J. E., Glover, G. H., & Gabrieli, J. D. E. (1999) · NeuroImage · doi:10.1006/nimg.1999.0441 · Cited by 1,448
Fast Spiral Coronary Artery Imaging
Meyer, C. H., Hu, B. S., Nishimura, D. G., & Macovski, A. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910280204 · Cited by 866
Self-citationSelf‐navigated spiral fMRI: Interleaved versus single‐shot
Glover, G. H., & Lai, S. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390305 · Cited by 476
Fast, iterative image reconstruction for MRI in the presence of field inhomogeneities
Sutton, B. P., Noll, D. C., & Fessler, J. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.808360 · Cited by 397
Self-citationNeural Response to Alcohol Stimuli in Adolescents With Alcohol Use Disorder
Tapert, S. F., Cheung, E. H., Brown, G. G., Frank, L. R., Paulus, M. P., Schweinsburg, A. D., Meloy, M. J., & Brown, S. A. (2003) · Archives of General Psychiatry · doi:10.1001/archpsyc.60.7.727 · Cited by 378
An approach to real-time magnetic resonance imaging for speech production
Narayanan, S., Nayak, K., Lee, S., Sethy, A., & Byrd, D. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1652588 · Cited by 313
Atkinson, D., Hill, D. L. G., Stoyle, P. N. R., Summers, P. E., & Keevil, S. F. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.650886 · Cited by 282
Three‐dimensional radial ultrashort echo‐time imaging with T2 adapted sampling
Rahmer, J., Börnert, P., Groen, J., & Bos, C. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20868 · Cited by 273
Small, S. L. (2002) · Brain · doi:10.1093/brain/awf148 · Cited by 272
Spiral K‐space MR imaging of cortical activation
Noll, D. C., Cohen, J. D., Meyer, C. H., & Schneider, W. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050112 · Cited by 254
Self-citationThe neural basis of visual skill learning: an fMRI study of mirror reading
Poldrack, R. (1998) · Cerebral Cortex · doi:10.1093/cercor/8.1.1 · Cited by 224
Metadata
- Authors
- Noll, D. C., Pauly, J. M., Meyer, C. H., Nishimura, D. G., & Macovskj, A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1992-06
- Volume
- 25
- Issue
- 2
- Pages
- 319-333
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2052800628
- Cited by
- 222
- References
- 0
- FWCI
- 5.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.