Fast Spiral Coronary Artery Imaging
Abstract
A flow‐independent method for imaging the coronary arteries within a breath‐hold on a standard whole‐body MR imager was developed. The technique is based on interleaved spiral k‐space scanning and forms a cardiac‐gated image in 20 heartbeats. The spiral readouts have good flow properties and generate minimal flow artifacts. The oblique slices are positioned so that the arteries are in the plane and so that the chamber blood does not obscure the arteries. Fat suppression by a spectral‐spatial pulse improves the visualization of the arteries.© 1992 Academic Press,Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multi-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813
Jackson, J. I., Meyer, C. H., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.97598 · Cited by 1,059
Self-citationSimultaneous spatial and spectral selective excitation
Meyer, C. H., Pauly, J. M., Macovskiand, A., & Nishimura, D. G. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910150211 · Cited by 498
Self-citationHigh-Speed Spiral-Scan Echo Planar NMR Imaging-I
Ahn, C. B., Kim, J. H., & Cho, Z. H. (1986) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1986.4307732 · Cited by 487
A Fast Sinc Function Gridding Algorithm for Fourier Inversion in Computer Tomography
O'Sullivan, J. D. (1985) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1985.4307723 · Cited by 482
Coronary arteries: breath-hold MR angiography.
Edelman, R. R., Manning, W. J., Burstein, D., & Paulin, S. (1991) · Radiology · doi:10.1148/radiology.181.3.1947074 · Cited by 361
A simple graphical representation of fourier-based imaging methods
Ljunggren, S. (1983) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(83)90060-4 · Cited by 292
A homogeneity correction method for magnetic resonance imaging with time-varying gradients
Noll, D. C., Meyer, C. H., Pauly, J. M., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.108599 · Cited by 277
Self-citationDeblurring for non‐2D fourier transform magnetic resonance imaging
Noll, D. C., Pauly, J. M., Meyer, C. H., Nishimura, D. G., & Macovskj, A. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250210 · Cited by 222
Self-citationSensory stimulation by time‐varying magnetic fields
Cohen, M. S., Weisskoff, R. M., Rzedzian, R. R., & Kantor, H. L. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140226 · Cited by 164
Physiological Effects of Fast Oscillating Magnetic Field Gradients
Budinger, T. F., Fischer, H., Hentschel, D., Reinfelder, H.-E., & Schmitt, F. (1991) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199111000-00001 · Cited by 141
Instant images of the human heart using a new, whole-body MR imaging system
Rzedzian, R. R., & Pykett, I. L. (1987) · American Journal of Roentgenology · doi:10.2214/ajr.149.2.245 · Cited by 139
Theoretical aspects of motion sensitivity and compensation in echo‐planar imaging
Duerk, J. L., & Simonetti, O. P. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010605 · Cited by 73
NMR angiography of coronary vessels with 2‐D planar image scanning
Cho, Z. H., Mun, C. W., & Friedenberg, R. M. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910200114 · Cited by 41
Cited by
Linear Systems Analysis of Functional Magnetic Resonance Imaging in Human V1
Boynton, G. M., Engel, S. A., Glover, G. H., & Heeger, D. J. (1996) · The Journal of Neuroscience · doi:10.1523/jneurosci.16-13-04207.1996 · Cited by 2,314
Lustig, M., Donoho, D. L., Santos, J. M., & Pauly, J. M. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914728 · Cited by 2,246
Retinotopic organization in human visual cortex and the spatial precision of functional MRI
Engel, S. (1997) · Cerebral Cortex · doi:10.1093/cercor/7.2.181 · Cited by 1,621
Advances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
Engel, S. A., Rumelhart, D. E., Wandell, B. A., Lee, A. T., Glover, G. H., Chichilnisky, E.-J., & Shadlen, M. N. (1994) · Nature · doi:10.1038/369525a0 · Cited by 990
Metadata
- Authors
- Meyer, C. H., Hu, B. S., Nishimura, D. G., & Macovski, A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1992-12
- Volume
- 28
- Issue
- 2
- Pages
- 202-213
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2105265911
- Cited by
- 866
- References
- 14
- FWCI
- 25.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.