Proton Relaxation Studies of Water Compartmentalization in a Model Neurological System
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Proton relaxation measurements from 18 crayfish abdominal nerve cords (a model of human CNS) are used to demonstrate that the transverse (though not the longitudinal) relaxation can be decomposed into four reproducible components that, in conjunction with optical and electron microscopy of the morphology, can be assigned to three water compartments within the cord and possibly to the mobile lipid protons. The assignments are extraaxonal water protons (32 ± 9% and mean T2 = 600 ± 200 ms), axonal water protons (59 ± 12% and mean T2 = 200 ± 30 ms), intramyelinic water protons (7 ± 4% and mean T2 = 50 ± 20 ms), and finally an unsubstantiated assignment of lipid protons (2.0 ± 2.0% and mean T2 = 7 ± 4 ms).© 1992 Academic Press,Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Modified Spin-Echo Method for Measuring Nuclear Relaxation Times
Meiboom, S., & Gill, D. (1958) · Review of Scientific Instruments · doi:10.1063/1.1716296 · Cited by 6,022
Cited by
In vivo visualization of myelin water in brain by magnetic resonance
Mackay, A., Whittall, K., Adler, J., Li, D., Paty, D., & Graeb, D. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310614 · Cited by 914
Magnetic Resonance Imaging of Myelin
Laule, C., Vavasour, I. M., Kolind, S. H., Li, D. K. B., Traboulsee, T. L., Moore, G. R. W., & MacKay, A. L. (2007) · Neurotherapeutics · doi:10.1016/j.nurt.2007.05.004 · Cited by 334
Quantitative magnetic resonance imaging of brain anatomy and in vivo histology
Weiskopf, N., Edwards, L. J., Helms, G., Mohammadi, S., & Kirilina, E. (2021) · Nature Reviews Physics · doi:10.1038/s42254-021-00326-1 · Cited by 300
MRI‐based myelin water imaging: A technical review
Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25198 · Cited by 285
Arshad, M., Stanley, J. A., & Raz, N. (2017) · Human Brain Mapping · doi:10.1002/hbm.23481 · Cited by 131
“The first index, MWF, is based on modeling the multiple-echo water signal with multiple T2 relaxation times and determining the contribution of the short T2 relaxation time constant or component, which is proportional to the amount of the water trapped between the myelin sheaths [Curnes et al., 1988; Menon et al., 199…”
BackgroundMethod
Metadata
- Authors
- Menon, R. S., Rusinko, M. S., & Allen, P. S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1992-12
- Volume
- 28
- Issue
- 2
- Pages
- 264-274
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2062118197
- Cited by
- 87
- References
- 2
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Proton Relaxation Studies of Water Compartmentalization in a Model Neurological System. https://app.cochat.ai/papers/10.1002/mrm.1910280208
- The paper
- Menon, R. S., Rusinko, M. S., & Allen, P. S. (1992). Proton Relaxation Studies of Water Compartmentalization in a Model Neurological System. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910280208
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.