CoChat

Imaging time reduction through multiple receiver coil data acquisition and image reconstruction

Carlson, J. W., Minemura, T. · 1993 · Magnetic Resonance in Medicine
Cited by 120

The DOI matches its Crossref record.

Abstract

A technique is described for the simultaneous acquisition of MRI data using two independent receiver coils surrounding the same region of tissue, which enables the collection of data necessary for image reconstruction in a reduced number of phase‐encoded acquisitions. This results in a 50% reduction in minimum scan time and may be useful in time‐critical procedures. The algorithm and imaging procedures are described, and example images are shown that illustrate the reconstruction. Signal to noise is decreased by the square root of the time savings, making this technique applicable to cases in which the need to decrease minimum scan time outweighs the signal to noise penalty.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910290516

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 120

Metadata

Authors
Carlson, J. W., & Minemura, T.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1993-05
Volume
29
Issue
5
Pages
681-687
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1986109830
Cited by
120
References
0
FWCI
0.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Imaging time reduction through multiple receiver coil data acquisition and image reconstruction. https://app.cochat.ai/papers/10.1002/mrm.1910290516
The paper
Carlson, J. W., & Minemura, T. (1993). Imaging time reduction through multiple receiver coil data acquisition and image reconstruction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910290516

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.