The DOI matches its Crossref record.
Dendrimer‐based metal chelates: A new class of magnetic resonance imaging contrast agents
Abstract
We have developed a new class of magnetic resonance imaging contrast agents with large proton relaxation enhancements and high molecular relaxivities. The reagents are built from the polyamidoamine form of Starburs™ dendrimers in which free amines have been conjugated to the chelator 2‐(4‐isothiocyanatobnenzyl)‐6‐methyl‐diethylenetriaminepenta‐acetic acid. The dendrimer gadolinium poly‐chelates have enhancement factors, i.e., the ratlo of the relaxivity per Gd(III) ion to that of Gd(III)‐diethylenetriaminepentaacetic acid, of up to 6. These factors are more than twice those observed for analogous metal‐chelate conjugates formed with serum albumins, polylysine, or dextran. One of the dendrimer‐metal chelate conjugates has 170 gadolinium ions bound, which greatly exceeds the number bound to other macromolecular agents reported In the literature, and has a molecular relaxivity of 5,800 (m M · s)−1, at 25 MHz, 20°C, and pH of 7.4. We observed that these dendrimer‐based agents enhance conventional MR images and 3D time of flight MR angiograms, and that those with molecular weights of 8,508 and 139,000 g/mole have enhancement half lives of 40 ± 10 and 200 ± 100 min, much longer than the 24 ± 4 min measured for Gd(III)‐diethylenetriaminepentaacetic acid. Our results suggest that this new and powerful class of contrast agents have the potential for diverse and extensive application in MR imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Longmire, M., Choyke, P. L., & Kobayashi, H. (2008) · Nanomedicine · doi:10.2217/17435889.3.5.703 · Cited by 2,149
Dendrimers in biomedical applications—reflections on the field
SVENSON, S., & TOMALIA, D. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2005.09.018 · Cited by 1,919
Self-citationTomalia, D. A. (2005) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2005.01.007 · Cited by 1,115
Self-citationTargeted therapy in chronic diseases using nanomaterial-based drug delivery vehicles
Singh, A. P., Biswas, A., Shukla, A., & Maiti, P. (2019) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-019-0068-3 · Cited by 645
Villaraza, A. J. L., Bumb, A., & Brechbiel, M. W. (2010) · Chemical Reviews · doi:10.1021/cr900232t · Cited by 632
Self-citation
Metadata
- Authors
- Wiener, E., Brechbiel, M. W., Brothers, H., Magin, R. L., Gansow, O. A., Tomalia, D. A., & Lauterbur, P. C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1994-01
- Volume
- 31
- Issue
- 1
- Pages
- 1-8
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2055876104
- Cited by
- 718
- References
- 0
- FWCI
- 16.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dendrimer‐based metal chelates: A new class of magnetic resonance imaging contrast agents. https://app.cochat.ai/papers/10.1002/mrm.1910310102
- The paper
- Wiener, E., Brechbiel, M. W., Brothers, H., Magin, R. L., Gansow, O. A., Tomalia, D. A., & Lauterbur, P. C. (1994). Dendrimer‐based metal chelates: A new class of magnetic resonance imaging contrast agents. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910310102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.