Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 246

The DOI matches its Crossref record.

Automated single‐voxel proton MRS: Technical development and multisite verification

Webb, Peter G., Sailasuta, Napapon, Kohler, Susan J., Raidy, Tom, Moats, Rex A., Hurd, Ralph·1994·Magnetic Resonance in Medicine

Abstract

To improve clinical utility, an integrated method has been developed to automatically acquire and process single‐voxel in vivo proton spectra on a 1.5 T clinical scanner. This method includes automated adjustment of linear shims using a very rapid modified simplex method, automated water suppression, and applies a water referencing scheme to correct for phase and residual eddy current effects. No operator intervention is required for the acquisition and processing of these pure‐absorption spectra. This method was tested in a preliminary multisite trial to determine intersite and intrasite variability of metabolite ratio measurements. In a sample of over 100 examinations, the standard deviation of the ratios NAA:Cr, Cho:Cr, and ml:Cr were found to be under 15% when using this method, a substantially narrower range than has been found In studies relying on manual adjustment of the instrument and/or manual processing. This result indicates that automated setting of acquisition and processing parameters is of critical importance in the clinical application of in vivo spectroscopy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910310404

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 246

Metadata

Authors
Webb, P. G., Sailasuta, N., Kohler, S. J., Raidy, T., Moats, R. A., & Hurd, R.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1994-04
Volume
31
Issue
4
Pages
365-373
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2083865676
Cited by
246
References
0
FWCI
12.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated single‐voxel proton MRS: Technical development and multisite verification. https://app.cochat.ai/papers/10.1002/mrm.1910310404
The paper
Webb, P. G., Sailasuta, N., Kohler, S. J., Raidy, T., Moats, R. A., & Hurd, R. (1994). Automated single‐voxel proton MRS: Technical development and multisite verification. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910310404

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.