The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
High frequency volume coils for clinical NMR imaging and spectroscopy
Abstract
A tuned transmission line resonator has been developed in theory and in practical design for the clinical NMR volume coil application at 4.1 tesla. The distributed circuit transmission line resonator was designed for high frequency, large conductive volume applications where conventional lumped element coil designs perform less efficiently. The resonator design has made use of a resonant coaxial cavity, which could be variably tuned to the Larmor frequency of interest by tunable transmission line elements. Large head‐ and body‐sized volumes, high efficiencies, and broad tuning ranges have been shown to be characteristic of the transmission line resonator to frequencies of 500 MHz. The B 1 homogeneity of the resonator has been demonstrated to be a function of the electromagnetic properties of the load itself. By numerically solving Maxwell's: equations for the fully time‐dependent B 1 field, coil homogeneity was predicted with finite‐element models of anatomic structure, and inhomogeneities corrected for. A how‐to exposition of coil design and construction has been included. Simple methods of quadrature driving and double tuning the transmission line resonator have also been presented. Human head images obtained with a tuned transmission line resonator at 175 MHz have clearly demonstrated uncompromised high field advantages of signal‐to‐noise and spatial resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microwave Filters, Impedance-Matching Networks, and Coupling Structures
Matthaei, G. L., Young, L., & Jones, E. (1980) · CERN Document Server (European Organization for Nuclear Research) · Cited by 4,361
Physical properties of tissue: F. A. Duck Harcourt Brace Jovanovich Ltd, London; 1990, 346 pp.
Bowker, P. (1991) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(91)90034-5 · Cited by 608
Comparison of linear and circular polarization for magnetic resonance imaging
Glover, G. H., Hayes, C. E., Pelc, N. J., Edelstein, W. A., Mueller, O. M., Hart, H. R., Hardy, C. J., O'Donnell, M., & Barber, W. D. (1985) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(85)90349-x · Cited by 265
Microwave Devices and Circuits
Potok, M. (1980) · Electronics and Power · doi:10.1049/ep.1980.0308 · Cited by 257
The theory of the bird-cage resonator
Tropp, J. S. (1989) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(89)90164-9 · Cited by 147
In vivo magnetic resonance imaging and spectroscopy of humans with a 4 t whole‐body magnet
Barfuss, H., Fischer, H., Hentschel, D., Ladebeck, R., Oppelt, A., Wittig, R., Duerr, W., & Oppelt, R. (1990) · NMR in Biomedicine · doi:10.1002/nbm.1940030106 · Cited by 119
Spectroscopy and imaging with a 4 tesla whole‐body mr system
Bomsdorf, H., Helzel, T., Kunz, D., Röschmann, P., Tschendel, O., & Wieland, J. (1988) · NMR in Biomedicine · doi:10.1002/nbm.1940010308 · Cited by 110
High resolution neuroimaging at 4.1 T
Pan, J. W., Vaughan, J. T., Kuzniecky, R., et al. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(95)02002-b · Cited by 56
Self-citationCirrhosis: Multiobserver analysis of hepatic MR imaging findings in a heterogeneous population
Mitchell, D. G., Lovett, K. E., Hann, H. L., Ehrlich, S. M., Palazzo, J., & Rubin, R. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030204 · Cited by 28
Cited by
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
“[47] and Vaughan et al [55] respectively.”
7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890
Self-citationB1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil
Van de Moortele, P., Akgun, C., Adriany, G., Moeller, S., Ritter, J., Collins, C. M., Smith, M. B., Vaughan, J. T., & Uğurbil, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20708 · Cited by 468
Self-citationTransmit and receive transmission line arrays for 7 Tesla parallel imaging
Adriany, G., Van de Moortele, P., Wiesinger, F., Moeller, S., Strupp, J. P., Andersen, P., Snyder, C., Zhang, X., Chen, W., Pruessmann, K. P., et al. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20321 · Cited by 421
Gelman, N., Gorell, J. M., Barker, P. B., Savage, R. M., Spickler, E. M., Windham, J. P., & Knight, R. A. (1999) · Radiology · doi:10.1148/radiology.210.3.r99fe41759 · Cited by 373
Metadata
- Authors
- Vaughan, J. T., Hetherington, H. P., Otu, J. O., Pan, J. W., & Pohost, G. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1994-08
- Volume
- 32
- Issue
- 2
- Pages
- 206-218
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1996595200
- Cited by
- 374
- References
- 9
- FWCI
- 7.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.