The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Assessment of relative brain iron concentrations using T2‐weighted and T2*‐weighted MRI at 3 Tesla
Abstract
In this paper a new method is presented for the relative assessment of brain iron concentrations based on the evaluation of T 2 and T 2* ‐weighted images. A multiecho sequence is employed for rapid measurement of T 2 and T 2*, enabling calculation of the line broadening effect ( T 2′). Several groups have failed to show a correlation between T 2 and brain iron content. However, quantification of T 2′, and the associated relaxation rate R 2′, may provide a more specific relative measure of brain iron concentration. This may find application in the study of brain diseases, which cause associated changes in brain iron levels. A new method of field inhomogeneity correction is presented that allows the separation of global and local field inhomogeneities, leading to more accurate T 2* measurements and hence, T 2′ values. The combination of T 2*, and T 2‐weighted MRI methods enables the differentiation of Parlkinson's disease patients from normal age‐matched controls based on differences in iron content within the substantia nigra.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prudnikov, A. P., Brychkov, Y. A., Marichev, O. I., & Romer, R. H. (1988) · American Journal of Physics · doi:10.1119/1.15375 · Cited by 2,910
Dexter, D. T., Wells, F. R., Lee, A. J., Agid, F., Agid, Y., Jenner, P., & Marsden, C. D. (1989) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1989.tb07264.x · Cited by 1,149
Cited by
Neural responses during anticipation of a primary taste reward
O'Doherty, J. P., Deichmann, R., Critchley, H. D., & Dolan, R. J. (2002) · Neuron · doi:10.1016/s0896-6273(02)00603-7 · Cited by 1,076
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Optimized EPI for fMRI studies of the orbitofrontal cortex
Deichmann, R., Gottfried, J. A., Hutton, C., & Turner, R. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00073-9 · Cited by 821
Myelin and iron concentration in the human brain: a quantitative study of MRI contrast
Stüber, C., Morawski, M., Schäfer, A., Labadie, C., Wähnert, M., Leuze, C., Streicher, M., Barapatre, N., Reimann, K., Geyer, S., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.02.026 · Cited by 635
Metadata
- Authors
- Ordidge, R. J., Gorell, J. M., Deniau, J. C., Knight, R. A., & Helpern, J. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1994-09
- Volume
- 32
- Issue
- 3
- Pages
- 335-341
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1983432533
- Cited by
- 323
- References
- 2
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of relative brain iron concentrations using T2‐weighted and T2*‐weighted MRI at 3 Tesla. https://app.cochat.ai/papers/10.1002/mrm.1910320309
- The paper
- Ordidge, R. J., Gorell, J. M., Deniau, J. C., Knight, R. A., & Helpern, J. A. (1994). Assessment of relative brain iron concentrations using T2‐weighted and T2*‐weighted MRI at 3 Tesla. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910320309
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.