The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Assessment of relative brain iron concentrations using T2‐weighted and T2*‐weighted MRI at 3 Tesla
Abstract
In this paper a new method is presented for the relative assessment of brain iron concentrations based on the evaluation of T 2 and T 2* ‐weighted images. A multiecho sequence is employed for rapid measurement of T 2 and T 2*, enabling calculation of the line broadening effect ( T 2′). Several groups have failed to show a correlation between T 2 and brain iron content. However, quantification of T 2′, and the associated relaxation rate R 2′, may provide a more specific relative measure of brain iron concentration. This may find application in the study of brain diseases, which cause associated changes in brain iron levels. A new method of field inhomogeneity correction is presented that allows the separation of global and local field inhomogeneities, leading to more accurate T 2* measurements and hence, T 2′ values. The combination of T 2*, and T 2‐weighted MRI methods enables the differentiation of Parlkinson's disease patients from normal age‐matched controls based on differences in iron content within the substantia nigra.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Folstein, M. F., Folstein, S. E., & McHugh, P. R. (1975) · Journal of Psychiatric Research · doi:10.1016/0022-3956(75)90026-6 · Cited by 88,282
Prudnikov, A. P., Brychkov, Y. A., Marichev, O. I., & Romer, R. H. (1988) · American Journal of Physics · doi:10.1119/1.15375 · Cited by 2,910
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Dexter, D. T., Wells, F. R., Lee, A. J., Agid, F., Agid, Y., Jenner, P., & Marsden, C. D. (1989) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1989.tb07264.x · Cited by 1,149
Increased iron‐related MRI contrast in the substantia nigra in Parkinson's disease
Gorell, J. M., Ordidge, R. J., Brown, G. G., Deniau, J.-C., Buderer, N. M., & Helpern, J. A. (1995) · Neurology · doi:10.1212/wnl.45.6.1138 · Cited by 324
Self-citationDirect FLASH MR imaging of magnetic field inhomogeneities by gradient compensation
Frahm, J., Merboldt, K., & Hänicke, W. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910060412 · Cited by 228
Magnetic Resonance Imaging of Brain Iron
Drayer, B. P., Burger, P. C., Darwin, R. H., Riederer, S. J., Herfkens, R. J., & Johnson, G. A. (1986) · Europe PMC (PubMed Central) · Cited by 176
T 2 relaxation time in patients with Parkinson's disease
Antonini, A., Leenders, K. L., Meier, D., Oertel, W. H., Boesiger, P., & Anliker, M. (1993) · Neurology · doi:10.1212/wnl.43.4.697 · Cited by 168
Magnetic resonance imaging in Parkinson's disease and parkinsonian syndromes
Stern, M. B., Braffman, B. H., Skolnick, B. E., Hurtig, H. I., & Grossman, R. I. (1989) · Neurology · doi:10.1212/wnl.39.11.1524 · Cited by 165
Magnetic resonance imaging of the midbrain in Parkinson's disease
Duguid, J. R., Paz, R. D. L., & DeGroot, J. (1986) · Annals of Neurology · doi:10.1002/ana.410200618 · Cited by 138
T2 values in the human brain: comparison with quantitative assays of iron and ferritin.
Chen, J. C., Hardy, P., Clauberg, M., Joshi, J. G., Parravano, J. G., Deck, J. H. N., Henkelman, R. M., Becker, L. E., & Kucharczyk, W. (1989) · Radiology · doi:10.1148/radiology.173.2.2798884 · Cited by 108
Brooks, D. J., Luthert, P. J., Gadian, D. G., & MARSDEN, C. D. (1989) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.52.1.108 · Cited by 95
Biological Significance of Iron-Related Magnetic Resonance Imaging Changes in the Brain
Pujol, J., Junqué, C., Vendrell, P., Grau, J. M., Martí-Vilalta, J. L., Olivé, C., & Gili, J. (1992) · Archives of Neurology · doi:10.1001/archneur.1992.00530310053012 · Cited by 89
A New Frontier of Blood Imaging Using Susceptibility Effect and Tailored RF Pulses
Ro, Y. M., & Cho, Z. H. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910280206 · Cited by 18
Cited by
Metals in Neurobiology: Probing Their Chemistry and Biology with Molecular Imaging
Que, E. L., Domaille, D. W., & Chang, C. J. (2008) · Chemical Reviews · doi:10.1021/cr078203u · Cited by 2,061
Neural responses during anticipation of a primary taste reward
O'Doherty, J. P., Deichmann, R., Critchley, H. D., & Dolan, R. J. (2002) · Neuron · doi:10.1016/s0896-6273(02)00603-7 · Cited by 1,076
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Optimized EPI for fMRI studies of the orbitofrontal cortex
Deichmann, R., Gottfried, J. A., Hutton, C., & Turner, R. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00073-9 · Cited by 821
Metadata
- Authors
- Ordidge, R. J., Gorell, J. M., Deniau, J. C., Knight, R. A., & Helpern, J. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1994-09
- Volume
- 32
- Issue
- 3
- Pages
- 335-341
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1983432533
- Cited by
- 323
- References
- 14
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.