Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 228

The DOI matches its Crossref record.

Direct FLASH MR imaging of magnetic field inhomogeneities by gradient compensation

Frahm, Jens, Merboldt, Klaus‐Dietmar, Hänicke, Wolfgang·1988·Magnetic Resonance in Medicine

Abstract

MR images based on gradient echoes are sensitive to artifacts caused by inhomogeneities of the static magnetic field. This paper describes the effects of local gradients in rapid FLASH MR images and presents a way of directly imaging affected areas. The idea is to compensate for signal losses due to mutual cancellation of dephased magnetizations by deliberate “misadjustments” of the refocusing part of the slice selection gradient. In contrast to conventional field imaging techniques no three‐dimensional data acquisition or subsequent Fourier analysis is required to obtain images at a particular gradient strength. Conventional as well as inhomogeneity compensated FLASH images have been obtained on phantoms and human heads using a 2.35‐T 40‐cm magnet and a 1.5‐T whole‐body system, respectively. © 1988 Academic Press, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910060412

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 228

Metadata

Authors
Frahm, J., Merboldt, K., & Hänicke, W.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1988-04
Volume
6
Issue
4
Pages
474-480
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2077187614
Cited by
228
References
0
FWCI
2.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Direct FLASH MR imaging of magnetic field inhomogeneities by gradient compensation. https://app.cochat.ai/papers/10.1002/mrm.1910060412
The paper
Frahm, J., Merboldt, K., & Hänicke, W. (1988). Direct FLASH MR imaging of magnetic field inhomogeneities by gradient compensation. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910060412

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.