The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Analysis and correction of motion artifacts in diffusion weighted imaging
Abstract
For diffusion‐weighted magnetic resonance imaging and under circumstances where patient movement can be modeled as rigid body motion, it is shown both theoretically and experimentally that translations and rotations produce phase errors which are zero‐ and first‐order, respectively, in position. Whlile a navigator echo can be used to correct the imaging data for arbitrary translations, only when the diffusion gradient is applied in the phase encode direction is there sufficient information to correct for rotations around all axes, and therefore for general rigid body motion. Experiments in test objects and human brain imaging confirm theoretical predictions and demonstrate that appropriate corrections dramatically improve image quality in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Cited by
White matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
Looking into the functional architecture of the brain with diffusion MRI.
Le Bihan, D. (2003) · Nature Reviews Neuroscience · doi:10.1038/nrn1119 · Cited by 1,571
Water diffusion changes in wallerian degeneration and their dependence on white matter architecture
Pierpaoli, C., Barnett, A., Pajevic, S., Chen, R., Penix, L., Virta, A., & Basser, P. (2001) · NeuroImage · doi:10.1006/nimg.2001.0765 · Cited by 938
Spurious group differences due to head motion in a diffusion MRI study
Yendiki, A., Koldewyn, K., Kakunoori, S., Kanwisher, N., & Fischl, B. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.11.027 · Cited by 508
Clinical intravoxel incoherent motion and diffusion MR imaging: Past, present, and future
Iima, M., & Le Bihan, D. (2016) · Radiology · doi:10.1148/radiol.2015150244 · Cited by 498
Metadata
- Authors
- Anderson, A. W., & Gore, J. C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1994-09
- Volume
- 32
- Issue
- 3
- Pages
- 379-387
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2158495596
- Cited by
- 393
- References
- 1
- FWCI
- 10.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis and correction of motion artifacts in diffusion weighted imaging. https://app.cochat.ai/papers/10.1002/mrm.1910320313
- The paper
- Anderson, A. W., & Gore, J. C. (1994). Analysis and correction of motion artifacts in diffusion weighted imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910320313
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.