Assessment of absolute metabolite concentrations in human tissue by 31P MRS in vivo. Part II: Muscle, liver, kidney
The DOI matches its Crossref record.
Abstract
Absolute metabolite concentrations were assessed in the muscle, the liver, and the kidney of healthy human volunteers by 31 P MRS. Fully relaxed in vivo spectra were acquired with a surface coil and were localized with an adiabatic lSlS pulse sequence. The spectra were quantified with a subsequent measurement of a calibration phantom and were processed iteratively in the time domain. The following mean metabolite concentrations (mmollliter) were measured in the resting male calf muscle (n = 9), in the fasting liver (n = 12), and in the orthiotopic kidney (n= 5): [PME] = 2.0 ± 0.6, 3.8 ± 0.7, and 2.6 ± 0.9, [Pi] = 2.9 ± 0.3, 1.8 ± 0.3, and 1.6 ± 0.4, [PDE] = 3.8 ± 0.8, 9.7 ± 1.5, and 4.9 ± 1.1, [PCr] = 22.0 ± 1.2, 0, and 0, [NTP] = 5.7 ± 0.4, 2.9 ± 0.4, and 2.0 ± 0.3, respectively. Several interesting findings are to be emphasized: The concentrations of Pi, PCr, and NTP were 20% lower in the muscle of women than of men. In addition, the pH, was significantly lower in female muscle (6.99 ± 0.03) than in male muscle (7.05 ± 0.03). The pH, in the liver (7.12 ± 0.09) and in the kidney (7.09 ± 0.08) were higher than in the muscle of both genders. The free magnesium concentration (mmollliter) was higher in the lliver (1.40 ± 0.64) than in the kidney (0.79 ± 0.39) and in the muscle (0.52 ± 0.10).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kemp, G. J., Meyerspeer, M., & Moser, E. (2007) · NMR in Biomedicine · doi:10.1002/nbm.1192 · Cited by 312
Pouwels, P. J. W., Brockmann, K., Kruse, B., Wilken, B., Wick, M., Hanefeld, F., & Frahm, J. (1999) · Pediatric Research · doi:10.1203/00006450-199910000-00019 · Cited by 309
Abnormal Hepatic Energy Homeostasis in Type 2 Diabetes†
Szendroedi, J., Chmelik, M., Schmid, A. I., Nowotny, P., Brehm, A., Krssak, M., Moser, E., & Roden, M. (2009) · Hepatology · doi:10.1002/hep.23093 · Cited by 204
Okada, M., Mitsunami, K., Inubushi, T., & Kinoshita, M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390515 · Cited by 60
Bansal, R., Hellerstein, D. J., Sawardekar, S., O’Neill, J., & Peterson, B. S. (2019) · PLOS ONE · doi:10.1371/journal.pone.0219679 · Cited by 8
Metadata
- Authors
- Buchli, R., Meier, D., Martin, E., & Boesiger, P.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1994-10
- Volume
- 32
- Issue
- 4
- Pages
- 453-458
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2030444682
- Cited by
- 92
- References
- 0
- FWCI
- 3.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of absolute metabolite concentrations in human tissue by 31P MRS in vivo. Part II: Muscle, liver, kidney. https://app.cochat.ai/papers/10.1002/mrm.1910320405
- The paper
- Buchli, R., Meier, D., Martin, E., & Boesiger, P. (1994). Assessment of absolute metabolite concentrations in human tissue by 31P MRS in vivo. Part II: Muscle, liver, kidney. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910320405
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.