Detection of apparent restricted diffusion in healthy rat brain at short diffusion times
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The application of bipolar diffusion sensitizing gradient pulses to significantly reduce the diffusion time is described. This approach is combined with the rapid U‐FLARE imaging sequence. Three diffusion‐sensitized types of experiments are compared and their suitability for detecting restricted diffusion is discussed. Experiments using a modification of the diffusion weighting by varying the diffusion time between 1.6 and 6.0 ms obtained nonmonoexponential signal attenuation curves from both healthy brains and postmortem. This behavior is indicative of restricted diffusion, but as it is detectable only at short diffusion times, in contrast to a restriction due to impermeable barriers, we have termed this “apparent restriction”.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moseley, M. E., Cohen, Y., Mintorovitch, J., Chileuitt, L., Shimizu, H., Kucharczyk, J., Wendland, M. F., & Weinstein, P. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140218 · Cited by 1,644
Cited by
Niendorf, T., Dijkhuizen, R. M., Norris, D. G., van Lookeren Campagne, M., & Nicolay, K. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360607 · Cited by 570
Self-citationMagnetic Resonance Imaging of Acute Stroke
Baird, A. E., & Warach, S. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199806000-00001 · Cited by 545
Bennett, K. M., Schmainda, K. M., Bennett (Tong), R., Rowe, D. B., Lu, H., & Hyde, J. S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10581 · Cited by 467
Lu, H., Jensen, J. H., Ramani, A., & Helpern, J. A. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1020 · Cited by 420
Quantitative magnetic resonance imaging of brain anatomy and in vivo histology
Weiskopf, N., Edwards, L. J., Helms, G., Mohammadi, S., & Kirilina, E. (2021) · Nature Reviews Physics · doi:10.1038/s42254-021-00326-1 · Cited by 300
Metadata
- Authors
- Niendorf, T., Norris, D. G., & Leibfritz, D.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1994-11
- Volume
- 32
- Issue
- 5
- Pages
- 672-677
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2002865004
- Cited by
- 65
- References
- 1
- FWCI
- 3.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.