Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 278

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Diffusion Weighting by the Trace of the Diffusion Tensor within a Single Scan

Mori, Susumu, Van Zijl, Peter C. M.·1995·Magnetic Resonance in Medicine

Abstract

The anisotropy of the water diffusion tensor inside brain causes contrast in diffusion images, which depends on the relative orientation of the diffusion gradients and the subject. Because the trace of a tensor is invariant upon rotation, measurement of this trace can reduce the orientation effect. A family of imaging pulse sequences is presented in which the signal intensity is weighted by the trace of the diffusion tensor in a single scan. The methods are demonstrated for chicken gizzard in several orientations with respect to the gradient frame of reference, and for ischemic injury in cat brain after middle cerebral artery occlusion. The sensitivity of the techniques to the presence of background gradients is measured and discussed in detail. As a result, pulse sequences are suggested that provide reliable diffusion constants in both homogeneous and inhomogeneous magnetic fields. The efficiency of the techniques for clinical application is also evaluated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910330107

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 278

Metadata

Authors
Mori, S., & Van Zijl, P. C. M.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1995-01
Volume
33
Issue
1
Pages
41-52
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1975528228
Cited by
278
References
1
FWCI
12.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.