Segmentation and Feature Extraction Techniques, with Applications to MRI Head Studies
The DOI matches its Crossref record.
Abstract
To obtain a three‐dimensional reconstruction of the hippocampus from a volumetric MRI head study, it is necessary to separate that structure not only from the surrounding white matter, but also from contiguous areas of gray matter–the amygdala and cerebral cortex. At present it is necessary for a physician to manually segment the hippocampus on each slice of the volume to obtain such a reconstruction. This process is time consuming, and is subject to inter‐ and intra‐operator variation as well as large discontinuities between slices. We propose a novel technique, making use of a combination of gray scale and edge‐detection algorithms and some a priori knowledge, by which a computer may make an unsupervised identification of a given structure through a series of contiguous images. This technique is applicable even if the structure includes so‐called false contours or missing contours. Applications include three‐dimensional reconstruction of difficult‐to‐segment regions of the brain, and volumetric measurements of structures from series of two‐dimensional images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Statistical approach to segmentation of single-channel cerebral MR images
Rajapakse, J. C., Giedd, J. N., & Rapoport, J. L. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563663 · Cited by 678
MR-based in vivo hippocampal volumetrics: 2. Findings in neuropsychiatric disorders
Geuze, E., Vermetten, E., & Bremner, J. D. (2005) · Molecular Psychiatry · doi:10.1038/sj.mp.4001579 · Cited by 412
Volumetric Analysis of the Prefrontal Cortex, Amygdala, and Hippocampus in Major Depression
Hastings, R. S., Parsey, R. V., Oquendo, M. A., Arango, V., & Mann, J. J. (2004) · Neuropsychopharmacology · doi:10.1038/sj.npp.1300371 · Cited by 378
“No significant correlations were observed between normalized volume determinations in the ROIs and clinical variables including age, total years of education, age at first episode of major depression, and number of major depressive episodes (data not shown).”
MethodInfluentialIntracranial volume change in childhood
Sgouros, S., Goldin, J. H., Hockley, A. D., Wake, M. J. C., & Natarajan, K. (1999) · Journal of Neurosurgery · doi:10.3171/jns.1999.91.4.0610 · Cited by 193
MR-based in vivo hippocampal volumetrics: 1. Review of methodologies currently employed
Geuze, E., Vermetten, E., & Bremner, J. D. (2005) · Molecular Psychiatry · doi:10.1038/sj.mp.4001580 · Cited by 185
Metadata
- Authors
- Ashton, E. A., Berg, M. J., Parker, K. J., Weisberg, J., Chen, C. W., & Ketonen, L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1995-05
- Volume
- 33
- Issue
- 5
- Pages
- 670-677
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2025274737
- Cited by
- 43
- References
- 0
- FWCI
- 5.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Segmentation and Feature Extraction Techniques, with Applications to MRI Head Studies. https://app.cochat.ai/papers/10.1002/mrm.1910330512
- The paper
- Ashton, E. A., Berg, M. J., Parker, K. J., Weisberg, J., Chen, C. W., & Ketonen, L. (1995). Segmentation and Feature Extraction Techniques, with Applications to MRI Head Studies. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910330512
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.