The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Coronary Angiography with Magnetization‐Prepared T2 Contrast
Abstract
A magnetization‐prepared, T2‐weighted sequence (T2 Prep) is used to suppress muscle and venous structures. When combined with lipid suppression, this technique improves the visualization of the coronary arteries. T2 Prep was designed to be robust in the presence of flow as well as B0 and B1 inho‐mogeneities and may be combined with virtually any imaging technique. Here, it is implemented with both a single‐slice spiral acquisition and a multi‐slice spiral method that acquires up to 15 slices in a single breath‐holding interval.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo
Wolff, S. D., & Balaban, R. S. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910100113 · Cited by 1,482
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Fast Spiral Coronary Artery Imaging
Meyer, C. H., Hu, B. S., Nishimura, D. G., & Macovski, A. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910280204 · Cited by 866
Self-citationSnapshot flash mri. applications to t1, t2, and chemical‐shift imaging
Haase, A. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130109 · Cited by 693
Blankenhorn, D. H., Azen, S. P., Kramsch, D. M., Mack, W. J., Cashin-Hemphill, L., Hodis, H. N., DeBoer, L. W. V., Mahrer, P. R., Masteller, M. J., Vailas, L. I., et al. (1993) · Annals of Internal Medicine · doi:10.7326/0003-4819-119-10-199311150-00002 · Cited by 637
A review of 1H nuclear magnetic resonance relaxation in pathology: Are T1 and T2 diagnostic?
Bottomley, P. A., Hardy, C. J., Argersinger, R. E., & Allen‐Moore, G. (1987) · Medical Physics · doi:10.1118/1.596111 · Cited by 471
Broadband heteronuclear decoupling
Levitt, M. H., Freeman, R., & Frenkiel, T. (1982) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(82)90124-x · Cited by 394
Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T
Wright, G. A., Hu, B. S., & Macovski, A. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010303 · Cited by 327
Self-citationCompensation for pulse imperfections in NMR spin-echo experiments
Levitt, M. H., & Freeman, R. (1981) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(81)90082-2 · Cited by 287
Fat-suppressed breath-hold magnetic resonance coronary angiography.
Manning, W. J., Li, W., Boyle, N. G., & Edelman, R. R. (1993) · Circulation · doi:10.1161/01.cir.87.1.94 · Cited by 282
Cited by
Stuber, M., Botnar, R. M., Danias, P. G., Sodickson, D. K., Kissinger, K. V., Van Cauteren, M., De Becker, J., & Manning, W. J. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00223-5 · Cited by 320
Stuber, M., Botnar, R. M., Danias, P. G., Kissinger, K. V., & Manning, W. J. (1999) · Radiology · doi:10.1148/radiology.212.2.r99au50579 · Cited by 256
Metadata
- Authors
- Brittain, J. H., Hu, B. S., Wright, G. A., Meyer, C. H., Macovski, A., & Nishimura, D. G.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1995-05
- Volume
- 33
- Issue
- 5
- Pages
- 689-696
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2110120304
- Cited by
- 448
- References
- 21
- FWCI
- 7.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coronary Angiography with Magnetization‐Prepared T2 Contrast. https://app.cochat.ai/papers/10.1002/mrm.1910330515
- The paper
- Brittain, J. H., Hu, B. S., Wright, G. A., Meyer, C. H., Macovski, A., & Nishimura, D. G. (1995). Coronary Angiography with Magnetization‐Prepared T2 Contrast. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910330515
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.