Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 327

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T

Wright, Graham A., Hu, Bob S., Macovski, Albert·1991·Journal of Magnetic Resonance Imaging

Abstract

The use of magnetic resonance (MR) imaging is investigated for noninvasively estimating the oxygen saturation of human blood (%HbO 2) in vivo by means of relaxation characteristics identified in earlier MR spectrometry studies. To this end, a sequence is presented for determining the T 2 of vascular blood in regions in which motions of the body and of the blood itself present a major challenge. With use of this sequence on a commercial 1.5‐T whole‐body imager, the relationship between the T 2 and %HbO 2 of blood is calibrated in vitro for the conditions expected in vivo. T 2 varies predictably from about 30 to 250 msec as %HbO 2 varies from 30% to 96%. T 2 values measured in situ for vascular blood in the mediastinum of several healthy subjects qualitatively reflected the behavior observed in vitro. Estimates of %HbO 2 for these vessels obtained with the in vitro calibration appear reasonable, particularly for venous blood, although difficulties arise in selecting the appropriate calibration factors. These encouraging initial results support a more systematic study of potential sources of error and an examination of the accuracy of in vivo measurements by comparison with direct measurements of %HbO 2 in vessels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.1880010303

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 327

Metadata

Authors
Wright, G. A., Hu, B. S., & Macovski, A.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
1991-05
Volume
1
Issue
3
Pages
275-283
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2009283203
Cited by
327
References
1
FWCI
2.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T. https://app.cochat.ai/papers/10.1002/jmri.1880010303
The paper
Wright, G. A., Hu, B. S., & Macovski, A. (1991). Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.1880010303

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.