The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Discrimination of Large Venous Vessels in Time‐Course Spiral Blood‐Oxygen‐Level‐Dependent Magnetic‐Resonance Functional Neuroimaging
Abstract
A technique is described for discriminating blood‐oxygen‐level‐dependent (BOLD) signal changes originating from large venous vessels and those that arise from the cortical parenchyma based on examining the temporal delay of each pixel's response. Photic stimulation experiments were performed with a conventional 1.5 T scanner and correlated each pixel's time‐course with sine and cosine functions at the frequency of the stimulus. It was found that the signal in pixels anatomically associated with gray matter was delayed between 4 and 8 s compared with the stimulus, whereas the signal in pixels correlated with visible vessels and sulci was generally delayed from 8 to 14 s. This larger delay is consistent with the longer time required for blood to reach the larger vessels. Finally, stimulus‐induced NMR phase changes were observed for the largest vessels, which are attributed to bulk susceptibility shifts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · Cited by 15,411
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
Ogawa, S., Lee, T., Nayak, A. S., & Glynn, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140108 · Cited by 2,266
Nonoxidative Glucose Consumption During Focal Physiologic Neural Activity
Fox, P. T., Raichle, M. E., Mintun, M. A., & Dence, C. (1988) · Science · doi:10.1126/science.3260686 · Cited by 1,796
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Processing strategies for time‐course data sets in functional mri of the human brain
Bandettini, P. A., Jesmanowicz, A., Wong, E. C., & Hyde, J. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300204 · Cited by 1,763
Jackson, J. I., Meyer, C. H., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.97598 · Cited by 1,059
Self-citationFast Spiral Coronary Artery Imaging
Meyer, C. H., Hu, B. S., Nishimura, D. G., & Macovski, A. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910280204 · Cited by 866
Self-citationCortical blood vessels of the human brain
Duvernoy, H. M., Delon, S., & Vannson, J. L. (1981) · Brain Research Bulletin · doi:10.1016/0361-9230(81)90007-1 · Cited by 839
Ogawa, S., & Lee, T. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160103 · Cited by 565
Cited by
Deconvolution of Impulse Response in Event-Related BOLD fMRI1
Glover, G. H. (1999) · NeuroImage · doi:10.1006/nimg.1998.0419 · Cited by 1,386
Self-citationUddin, L. Q., Clare Kelly, A. M., Biswal, B. B., Xavier Castellanos, F., & Milham, M. P. (2009) · Human Brain Mapping · doi:10.1002/hbm.20531 · Cited by 1,135
A functional imaging study of cooperation in two-person reciprocal exchange
McCabe, K., Houser, D., Ryan, L., Smith, V., & Trouard, T. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.211415698 · Cited by 984
Miezin, F. M., Maccotta, L., Ollinger, J. M., Petersen, S. E., & Buckner, R. L. (2000) · NeuroImage · doi:10.1006/nimg.2000.0568 · Cited by 944
A temporal comparison of BOLD, ASL, and NIRS hemodynamic responses to motor stimuli in adult humans
Huppert, T. J., Hoge, R. D., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.065 · Cited by 846
Metadata
- Authors
- Lee, A. T., Glover, G. H., & Meyer, C. H.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1995-06
- Volume
- 33
- Issue
- 6
- Pages
- 745-754
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2018162020
- Cited by
- 321
- References
- 17
- FWCI
- 22.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Discrimination of Large Venous Vessels in Time‐Course Spiral Blood‐Oxygen‐Level‐Dependent Magnetic‐Resonance Functional Neuroimaging. https://app.cochat.ai/papers/10.1002/mrm.1910330602
- The paper
- Lee, A. T., Glover, G. H., & Meyer, C. H. (1995). Discrimination of Large Venous Vessels in Time‐Course Spiral Blood‐Oxygen‐Level‐Dependent Magnetic‐Resonance Functional Neuroimaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910330602
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.