The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Theory of 1/T1 and 1/T2 NMRD profiles of solutions of magnetic nanoparticles
Abstract
Organically coated iron oxide crystallites with diameters of 5–50 nm (“nanoparticles”) are potential magnetic resonance imaging contrast agents. 1/T1 and 1/T2 of solvent water protons are increased dramatically by magnetic interactions in the “outer sphere” environment of the nanoparticles; subsequent diffusive mixing distributes this relaxation throughout the solvent. Published theory, valid for the solute magnetic energy small compared with thermal energy, is applicable to small magnetic solutes (e.g., gadolinium and manganese diethylenetriaminopentaacetic acid, and nitroxide free radicals) at generally accessible fields (≤ 50 T). It fails for nanoparticles at fields above ˜0.05 T, i.e., at most imaging fields. The authors have reformulated outer sphere relaxation theory to incorporate progressive magnetic saturation of solute nanoparticles and, in addition, indicate how to use empirical magnetization data for realistic particles when their magnetic properties are not ideal. It is important to handle the effects of rapid thermally induced reorientation of the magnetization of the nanoparticles (their “superparamagnetism”) effectively, including their sensitivity to particle size. The theoretical results are presented as the magnetic field dependence (NMRD profiles) of 1/T1 and 1/T2, normalized to Fe content, for three sizes of particles, and then compared with the limited data extant for well‐characterized material.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Solid State Physics
Kittel, C., & Fan, H. Y. (1957) · American Journal of Physics · doi:10.1119/1.1934457 · Cited by 22,240
Bean, C. P., & Livingston, J. D. (1959) · Journal of Applied Physics · doi:10.1063/1.2185850 · Cited by 1,773
Hwang, L.-P., & Freed, J. H. (1975) · The Journal of Chemical Physics · doi:10.1063/1.431841 · Cited by 600
Monocrystalline iron oxide nanocompounds (MION): Physicochemical properties
Shen, T., Weissleder, R., Papisov, M., Bogdanov, A., & Brady, T. J. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290504 · Cited by 499
Introduction to Solid State Physics
KITTEL, C., & Masi, J. F. (1954) · Physics Today · doi:10.1063/1.3061720 · Cited by 480
Freed, J. H. (1978) · The Journal of Chemical Physics · doi:10.1063/1.436302 · Cited by 442
Mössbauer studies of thermal excitations in magnetically ordered microcrystals
Mørup, S., & Topsøe, H. (1976) · Applied Physics · doi:10.1007/bf00895017 · Cited by 359
Gillis, P., & Koenig, S. H. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910050404 · Cited by 353
Self-citationNuclear relaxation in macromolecules by paramagnetic ions: a novel mechanism
Gueron, M. (1975) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(75)90029-3 · Cited by 327
Handbook of Metal-Ligand Interactions in Biological Fluids
Flodin, N. W. (1996) · Journal of the American College of Nutrition · doi:10.1080/07315724.1996.10738027 · Cited by 186
Transverse relaxivity of particulate MRI contrast media: From theories to experiments
Muller, R. N., Gillis, P., Moiny, F., & Roch, A. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910220203 · Cited by 171
Some Magnetic Properties of Magnetite (Fe3O4) Microcrystals
McNab, T. K., Fox, R. A., & Boyle, A. J. F. (1968) · Journal of Applied Physics · doi:10.1063/1.1656035 · Cited by 168
Der Translationsanteil der Protonenrelaxation in wäßrigen Lösungen paramagnetischer Ionen
Pfeifer, H. (1961) · Annalen der Physik · doi:10.1002/andp.19614630102 · Cited by 94
Investigation of the magnetic properties of iron oxide nanoparticles used as contrast agent for MRI
Pouliquen, D., Perroud, H., Calza, F., JALLET, P., & Jeune, J. J. L. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910240108 · Cited by 75
Dextran magnetite as a liver contrast agent
Magin, R. L., Bacic, G., Niesman, M. R., et al. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910200102 · Cited by 39
Target‐specific superparamagnetic MR contrast agents
Weissleder, R. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910220209 · Cited by 29
Cited by
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Artificially engineered magnetic nanoparticles for ultra-sensitive molecular imaging
Lee, J.-H., Huh, Y.-M., Jun, Y.-W., Seo, J.-W., Jang, J.-T., Song, H.-T., Kim, S., Cho, E.-J., Yoon, H.-G., Suh, J.-S., et al. (2007) · Nature Medicine · doi:10.1038/nm1467 · Cited by 1,897
Inorganic Nanoparticles for MRI Contrast Agents
Na, H. B., Song, I. C., & Hyeon, T. (2009) · Advanced Materials · doi:10.1002/adma.200802366 · Cited by 1,781
Magnetic Nanoparticles: Surface Effects and Properties Related to Biomedicine Applications
Issa, B., Obaidat, I., Albiss, B., & Haik, Y. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms141121266 · Cited by 1,245
Jun, Y.-W., Huh, Y.-M., Choi, J.-S., Lee, J.-H., Song, H.-T., Kim, S., Yoon, S., Kim, K.-S., Shin, J.-S., Suh, J.-S., et al. (2005) · Journal of the American Chemical Society · doi:10.1021/ja0422155 · Cited by 1,193
Metadata
- Authors
- Koenig, S. H., & Kellar, K. E.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1995-08
- Volume
- 34
- Issue
- 2
- Pages
- 227-233
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2171442859
- Cited by
- 314
- References
- 16
- FWCI
- 5.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.