The DOI matches its Crossref record.
Imaging myocardial fiber architecture in vivo with magnetic resonance
Abstract
Methods are presented to image the fiber architecture of the human myocardium in vitro and in vivo. NMR images are obtained of the diffusion anisotropy tensor, indicative of local myofiber orientation. Studies of cardiac necropsy specimens demonstrate classic features of ventricular myoarchitecture including the continuous endocardial to epicardial variation of fiber helix angles (angles to the ventricular circumferential direction) of approximatel ±1.3 to −1.3 radians. Cross‐fiber anisotropy is also observed. In the beating heart, NMR diffusion data must be corrected for the effects of myocardial deformation during the cardiac cycle. This correction can be performed using an independent MRI method to map the strain‐rate tensor field of the myocardium through time. Combining fiber orientation with local myocardial strain rate, local rates of myocardial fiber shortening may be computed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity
Tuch, D. S., Reese, T. G., Wiegell, M. R., Makris, N., Belliveau, J. W., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10268 · Cited by 1,548
Self-citationBasser, P. J. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080707 · Cited by 1,519
Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo
Reese, T. G., Heid, O., Weisskoff, R. M., & Wedeen, V. J. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10308 · Cited by 1,227
Self-citationA review of diffusion tensor imaging studies in schizophrenia
Kubicki, M., McCarley, R., Westin, C.-F., Park, H.-J., Maier, S., Kikinis, R., Jolesz, F. A., & Shenton, M. E. (2007) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2005.05.005 · Cited by 769
Diffusion MRI of complex neural architecture.
Tuch, D. S., Reese, T. G., Wiegell, M. R., & Wedeen, V. J. (2003) · Neuron · doi:10.1016/s0896-6273(03)00758-x · Cited by 698
Self-citation
Metadata
- Authors
- Reese, T. G., Weisskoff, R. M., Smith, R. N., Rosen, B. R., Dinsmore, R. E., & Wedeen, V. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1995-12
- Volume
- 34
- Issue
- 6
- Pages
- 786-791
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2062715079
- Cited by
- 292
- References
- 0
- FWCI
- 5.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Imaging myocardial fiber architecture in vivo with magnetic resonance. https://app.cochat.ai/papers/10.1002/mrm.1910340603
- The paper
- Reese, T. G., Weisskoff, R. M., Smith, R. N., Rosen, B. R., Dinsmore, R. E., & Wedeen, V. J. (1995). Imaging myocardial fiber architecture in vivo with magnetic resonance. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910340603
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.