The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Imaging myocardial fiber architecture in vivo with magnetic resonance
Abstract
Methods are presented to image the fiber architecture of the human myocardium in vitro and in vivo. NMR images are obtained of the diffusion anisotropy tensor, indicative of local myofiber orientation. Studies of cardiac necropsy specimens demonstrate classic features of ventricular myoarchitecture including the continuous endocardial to epicardial variation of fiber helix angles (angles to the ventricular circumferential direction) of approximatel ±1.3 to −1.3 radians. Cross‐fiber anisotropy is also observed. In the beating heart, NMR diffusion data must be corrected for the effects of myocardial deformation during the cardiac cycle. This correction can be performed using an independent MRI method to map the strain‐rate tensor field of the myocardium through time. Combining fiber orientation with local myocardial strain rate, local rates of myocardial fiber shortening may be computed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mathematical Foundations of Elasticity
Marsden, J. E., Hughes, T. J. R., & Carlson, D. E. (1984) · Journal of Applied Mechanics · doi:10.1115/1.3167757 · Cited by 2,665
Fiber Orientation in the Canine Left Ventricle during Diastole and Systole
STREETER, D. D., SPOTNITZ, H. M., PATEL, D. P., ROSS, J., & SONNENBLICK, E. H. (1969) · Circulation Research · doi:10.1161/01.res.24.3.339 · Cited by 1,454
Relation between transmural deformation and local myofiber direction in canine left ventricle.
Waldman, L. K., Nosan, D., Villarreal, F., & Covell, J. W. (1988) · Circulation Research · doi:10.1161/01.res.63.3.550 · Cited by 279
Mitchell, G. F., Lamas, G. A., Vaughan, D. E., & Pfeffer, M. A. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90314-d · Cited by 275
Anisotropy in diffusion‐weighted MRI
Moseley, M. E., Kucharczyk, J., Asgari, H. S., & Norman, D. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910190222 · Cited by 198
On the muscular architecture of the ventricles of the human heart
Mall, F. P. (1911) · American Journal of Anatomy · doi:10.1002/aja.1000110302 · Cited by 194
In vivo measurement of water diffusion in the human heart
Edelman, R. R., Gaa, J., Wedeen, V. J., Loh, E., Hare, J. M., Prasad, P. V., & Li, W. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320320 · Cited by 168
Self-citationMR Diffusion Imaging of the Human Brain
Chien, D., Buxton, R. B., Kwong, K. K., Brady, T. J., & Rosen, B. R. (1990) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199007000-00003 · Cited by 154
Self-citationMechanics of the left ventricle
Chadwick, R. S. (1982) · Biophysical Journal · doi:10.1016/s0006-3495(82)84518-9 · Cited by 139
Anisotropy of water diffusion in the myocardium of the rat.
Garrido, L., Wedeen, V. J., Kwong, K. K., Spencer, U. M., & Kantor, H. L. (1994) · Circulation Research · doi:10.1161/01.res.74.5.789 · Cited by 137
Self-citationAdaptation of cardiac structure by mechanical feedback in the environment of the cell: a model study
Arts, T. G. J., Prinzen, F. W., Snoeckx, L. H. E. H., Rijcken, J. M., & Reneman, R. S. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80876-8 · Cited by 98
Architecture of the human ventricular myocardium
Fox, C. C., & Hutchins, G. M. (1949) · American Heart Journal · doi:10.1016/0002-8703(49)91220-x · Cited by 90
Cited by
Toward a quantitative assessment of diffusion anisotropy
Pierpaoli, C., & Basser, P. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360612 · Cited by 2,405
High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity
Tuch, D. S., Reese, T. G., Wiegell, M. R., Makris, N., Belliveau, J. W., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10268 · Cited by 1,548
Self-citationBasser, P. J. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080707 · Cited by 1,519
Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo
Reese, T. G., Heid, O., Weisskoff, R. M., & Wedeen, V. J. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10308 · Cited by 1,227
Self-citationA review of diffusion tensor imaging studies in schizophrenia
Kubicki, M., McCarley, R., Westin, C.-F., Park, H.-J., Maier, S., Kikinis, R., Jolesz, F. A., & Shenton, M. E. (2007) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2005.05.005 · Cited by 769
Metadata
- Authors
- Reese, T. G., Weisskoff, R. M., Smith, R. N., Rosen, B. R., Dinsmore, R. E., & Wedeen, V. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1995-12
- Volume
- 34
- Issue
- 6
- Pages
- 786-791
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2062715079
- Cited by
- 292
- References
- 12
- FWCI
- 5.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.