The DOI matches its Crossref record.
The relation between brain iron and NMR relaxation times: An in vitro study
Abstract
T1 and T2 relaxation times and iron concentrations were measured in 24 specimens of gray matter from fresh human and monkey brains at magnetic fields from 0.05 to 1.5 Tesla. Three different effects were found that correlate with iron content: a T1‐shortening that falls off somewhat at high fields, a T2‐shortening that is field‐independent and thus important at low fields, and a contribution to 1/T2 that increases linearly with field strength. This linear field dependence has been seen only in ferritin and other ferric oxyhydroxide particles. Our results are in agreement with in vivo MRI studies and are generally consistent with values for ferritin solution, except for differences such as clustering of ferritin in tissue. A cerebral cavernous hemangioma specimen showed similar T2‐shortening, but with a 2.7 times larger magnitude, attributed to larger clusters of hemosiderin in macrophages. The dependence on interecho time 2T was measured in three brains; 1/T2 increased significantly for T up to 32 ms, as expected from the size of the ferritin clusters. These findings support the theory that ferritin iron is the primary determinant of MRI contrast in normal gray matter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Swain, R. A., Harris, A. B., Wiener, E. C., Dutka, M. V., Morris, H. D., Theien, B. E., Konda, S., Engberg, K., Lauterbur, P. C., & Greenough, W. T. (2003) · Neuroscience · doi:10.1016/s0306-4522(02)00664-4 · Cited by 655
Gelman, N., Gorell, J. M., Barker, P. B., Savage, R. M., Spickler, E. M., Windham, J. P., & Knight, R. A. (1999) · Radiology · doi:10.1148/radiology.210.3.r99fe41759 · Cited by 373
Callaghan, M. F., Freund, P., Draganski, B., Anderson, E., Cappelletti, M., Chowdhury, R., Diedrichsen, J., FitzGerald, T. H. B., Smittenaar, P., Helms, G., et al. (2014) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2014.02.008 · Cited by 292
Raven, E. P., Lu, P. H., Tishler, T. A., Heydari, P., & Bartzokis, G. (2013) · Journal of Alzheimer s Disease · doi:10.3233/jad-130209 · Cited by 270
Metadata
- Authors
- Vymazal, J., Brooks, R. A., Baumgarner, C., Tran, V., Katz, D., Bulte, J. W. M., Bauminger, E. R., & Chiro, G. D.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1996-01
- Volume
- 35
- Issue
- 1
- Pages
- 56-61
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2008797191
- Cited by
- 172
- References
- 0
- FWCI
- 5.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The relation between brain iron and NMR relaxation times: An in vitro study. https://app.cochat.ai/papers/10.1002/mrm.1910350108
- The paper
- Vymazal, J., Brooks, R. A., Baumgarner, C., Tran, V., Katz, D., Bulte, J. W. M., Bauminger, E. R., & Chiro, G. D. (1996). The relation between brain iron and NMR relaxation times: An in vitro study. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910350108
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.