The DOI matches its Crossref record.
Quantitative 1H spectroscopic imaging of human brain at 4.1 T using image segmentation
Abstract
Metabolic differences in the content of N‐acetylaspartate (NAA), creatine (CR), and choline (CH) in cerebral gray and white matter can complicate the interpretation of 1 H spectroscopic images. To account for these variations, the gray‐and white‐matter content of each voxel must be known. To provide these data, a T1‐based image segmentation scheme was implemented at 4.1 T. The tissue composition of each voxel was determined using the point‐spread function of the spectroscopic imaging acquisition and the segmented anatomical image. Pure gray‐ and white‐matter values for CR/NAA and CH/NAA, and the content of CR, CH, and NAA, were determined using a linear‐regression analysis of 984 voxels acquired from 10 subjects using white‐matter CR as an internal standard. This information was used to establish means and confidence intervals for CR/NAA and CH/NAA from a voxel of arbitrary tissue composition. Using a single‐tailed t test, the extent and locations of the metabolic abnormalities (P < 0.05) in a patient with multiple sclerosis were identified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Subtype-Specific Alterations of γ-Aminobutyric Acid and Glutamatein Patients With Major Depression
Sanacora, G., Gueorguieva, R., Epperson, C. N., Wu, Y.-T., Appel, M., Rothman, D. L., Krystal, J. H., & Mason, G. F. (2004) · Archives of General Psychiatry · doi:10.1001/archpsyc.61.7.705 · Cited by 796
Self-citationUse of tissue water as a concentration reference for proton spectroscopic imaging
Gasparovic, C., Song, T., Devier, D., Bockholt, H. J., Caprihan, A., Mullins, P. G., Posse, S., Jung, R. E., & Morrison, L. A. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20901 · Cited by 509
Regional metabolite concentrations in human brain as determined by quantitative localized proton MRS
Pouwels, P. J. W., & Frahm, J. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390110 · Cited by 465
Issues of spectral quality in clinical 1H‐magnetic resonance spectroscopy and a gallery of artifacts
Kreis, R. (2004) · NMR in Biomedicine · doi:10.1002/nbm.891 · Cited by 430
1H MR Spectroscopy of the Brain: Absolute Quantification of Metabolites
Jansen, J. F. A., Backes, W. H., Nicolay, K., & Kooi, M. E. (2006) · Radiology · doi:10.1148/radiol.2402050314 · Cited by 405
Metadata
- Authors
- Hetherington, H. P., Pan, J. W., Mason, G. F., Adams, D., Vaughn, M. J., Twieg, D. B., & Pohost, G. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1996-07
- Volume
- 36
- Issue
- 1
- Pages
- 21-29
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2075789321
- Cited by
- 195
- References
- 0
- FWCI
- 14.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative 1H spectroscopic imaging of human brain at 4.1 T using image segmentation. https://app.cochat.ai/papers/10.1002/mrm.1910360106
- The paper
- Hetherington, H. P., Pan, J. W., Mason, G. F., Adams, D., Vaughn, M. J., Twieg, D. B., & Pohost, G. M. (1996). Quantitative 1H spectroscopic imaging of human brain at 4.1 T using image segmentation. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910360106
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.