T1 and T2 of ferritin solutions: Effect of loading factor
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Proton magnetic relaxation times T1 and T2 were measured at field strengths from 0.05 T to 1.5 T in solutions of ferritin with loading factors from 90 to 3600 iron atoms per molecule. 1/T2 increased linearly with field strength, as previously observed, and the slope per unit iron was approximately the same in all samples. This latter finding indicates that the field dependence of T2 may be used as a measure of ferritin‐bound iron, regardless of loading factor. A possible explanation is presented, based on the presumed antiferromagnetic structure of the ferritin core and the linear dependence of 1/T2 on core magnetization. A nonzero contribution to 1/T2 in the limit of low field and a contribution to 1/T1 were also found, both of which increase linearly with loading factor for constant protein concentration; these effects represent quantum mechanical dipole‐dipole relaxation of water protons either by iron atoms on the surface of the core or by the iron core itself. Finally, the extrapolated intercept at LF = 0 for both 1/T1 and 1/T2 indicates a contribution from a small number of iron ions bound to the protein shell. These results may help in the use of MRI to measure brain iron and possibly even ferritin loading factor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Cited by
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
A new transgene reporter for in vivo magnetic resonance imaging
Genove, G., DeMarco, U., Xu, H., Goins, W. F., & Ahrens, E. T. (2005) · Nature Medicine · doi:10.1038/nm1208 · Cited by 423
Vymazal, J., Righini, A., Brooks, R. A., Canesi, M., Mariani, C., Leonardi, M., & Pezzoli, G. (1999) · Radiology · doi:10.1148/radiology.211.2.r99ma53489 · Cited by 342
Self-citationBrain ferritin iron may influence age- and gender-related risks of neurodegeneration
Bartzokis, G., Tishler, T. A., Lu, P. H., Villablanca, P., Altshuler, L. L., Carter, M., Huang, D., Edwards, N., & Mintz, J. (2007) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2006.02.005 · Cited by 341
Cohen, B., Dafni, H., Meir, G., Harmelin, A., & Neeman, M. (2005) · Neoplasia · doi:10.1593/neo.04436 · Cited by 322
Metadata
- Authors
- Vymazal, J., Zak, O., Bulte, J. W. M., Aisen, P., & Brooks, R. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1996-07
- Volume
- 36
- Issue
- 1
- Pages
- 61-65
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1982808423
- Cited by
- 84
- References
- 1
- FWCI
- 4.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: T1 and T2 of ferritin solutions: Effect of loading factor. https://app.cochat.ai/papers/10.1002/mrm.1910360111
- The paper
- Vymazal, J., Zak, O., Bulte, J. W. M., Aisen, P., & Brooks, R. A. (1996). T1 and T2 of ferritin solutions: Effect of loading factor. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910360111
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.