Correction for distortion of echo‐planar images used to calculate the apparent diffusion coefficient
Abstract
An algorithm for correcting the distortions that occur in diffusion‐weighted echo‐planar images due to the strong diffusion‐sensitizing gradients is presented. The dominant distortions may be considered to be only changes of scale coupled with a shear and linear translation in the phase‐encoding direction. It is then possible to correct for them by using an algorithm in which each line of the image in the phase‐encoding direction is considered in turn, with only one parameter (the scale) to be found by searching.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Echo-planar imaging of intravoxel incoherent motion.
Turner, R., Le Bihan, D., Maier, J., Vavrek, R., Hedges, L. K., & Pekar, J. (1990) · Radiology · doi:10.1148/radiology.177.2.2217777 · Cited by 581
Identification of “Premyelination” by Diffusion-Weighted MRI
Wimberger, D. M., Roberts, T. P., Barkovich, A. J., Prayer, L. M., Moseley, M. E., & Kucharczyk, J. (1995) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199501000-00005 · Cited by 342
Diffusion imaging of the human brain in vivo using high‐speed STEAM MRI
Merboldt, K., Hänicke, W., Bruhn, H., Gyngell, M. L., & Frahm, J. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230119 · Cited by 90
Diffusion/perfusion MR imaging of the brain: from structure to function.
Bihan, D. L. (1990) · Radiology · doi:10.1148/radiology.177.2.2217762 · Cited by 83
Cited by
Diffusion tensor imaging of the brain
Alexander, A. L., Lee, J. E., Lazar, M., & Field, A. S. (2007) · Neurotherapeutics · doi:10.1016/j.nurt.2007.05.011 · Cited by 2,747
Diffusion‐tensor MRI: theory, experimental design and data analysis – a technical review
Basser, P. J., & Jones, D. K. (2002) · NMR in Biomedicine · doi:10.1002/nbm.783 · Cited by 1,478
Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo
Reese, T. G., Heid, O., Weisskoff, R. M., & Wedeen, V. J. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10308 · Cited by 1,227
Log-Euclidean metrics for fast and simple calculus on diffusion tensors
Arsigny, V., Fillard, P., Pennec, X., & Ayache, N. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20965 · Cited by 1,113
Advances in diffusion MRI acquisition and processing in the Human Connectome Project
Sotiropoulos, S. N., Jbabdi, S., Xu, J., Andersson, J. L., Moeller, S., Auerbach, E. J., Glasser, M. F., Hernandez, M., Sapiro, G., Jenkinson, M., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.057 · Cited by 891
Metadata
- Authors
- Haselgrove, J. C., & Moore, J. R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1996-12
- Volume
- 36
- Issue
- 6
- Pages
- 960-964
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2027864333
- Cited by
- 324
- References
- 5
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Correction for distortion of echo‐planar images used to calculate the apparent diffusion coefficient. https://app.cochat.ai/papers/10.1002/mrm.1910360620
- The paper
- Haselgrove, J. C., & Moore, J. R. (1996). Correction for distortion of echo‐planar images used to calculate the apparent diffusion coefficient. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910360620
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.