Multi‐gradient echo with susceptibility inhomogeneity compensation (MGESIC): Demonstration of f MRI in the olfactory cortex at 3.0 T
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Short image acquisition times and sensitivity to magnetic susceptibility favor the use of gradient echo imaging methods in functional MRI (f MRI). However, magnetic susceptibility effects attributed to air‐tissue interfaces also lead to severe signal loss in images of the large inferior frontal and lateral temporal cortices of the human brain, which renders these regions inaccessible to f MRI. The signal loss is caused by the local field gradients in the slice selection direction. A multigradient echo with magnetic susceptibility inhomogeneity compensation method (MGESIC) is proposed to overcome this problem. The MGESIC method effectively corrects the susceptibility artifacts and maintains the advantages of gradient echo methods to both BOLD sensitivity and fast image acquisition. The effectiveness of the MGESIC method is demonstrated by f MRI experimental results within the olfactory cortex.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Cited by
Overview of Functional Magnetic Resonance Imaging
Glover, G. H. (2011) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2010.11.001 · Cited by 1,024
Spiral‐in/out BOLD fMRI for increased SNR and reduced susceptibility artifacts
Glover, G. H., & Law, C. S. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1222 · Cited by 599
Susceptibility-Induced Loss of Signal: Comparing PET and fMRI on a Semantic Task
Devlin, J. T., Russell, R. P., Davis, M. H., Price, C. J., Wilson, J., Moss, H. E., Matthews, P. M., & Tyler, L. K. (2000) · NeuroImage · doi:10.1006/nimg.2000.0595 · Cited by 439
Poser, B. A., Versluis, M. J., Hoogduin, J. M., & Norris, D. G. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20900 · Cited by 439
ON THE CHARACTERISTICS OF FUNCTIONAL MAGNETIC RESONANCE IMAGING OF THE BRAIN
Ogawa, S., Menon, R. S., Kim, S.-G., & Ugurbil, K. (1998) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.27.1.447 · Cited by 343
Time Course of Odorant-Induced Activation in the Human Primary Olfactory Cortex
Sobel, N., Prabhakaran, V., Zhao, Z., Desmond, J. E., Glover, G. H., Sullivan, E. V., & Gabrieli, J. D. E. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.83.1.537 · Cited by 265
Analysis of wave behavior in lossy dielectric samples at high field
Yang, Q. X., Wang, J., Zhang, X., Collins, C. M., Smith, M. B., Liu, H., Zhu, X., Vaughan, J. T., Ugurbil, K., & Chen, W. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10137 · Cited by 255
Self-citationCompensation of susceptibility-induced bold sensitivity losses in echo-planar fMRI imaging
Deichmann, R., Josephs, O., Hutton, C., Corfield, D. R., & Turner, R. (2002) · NeuroImage · doi:10.1006/nimg.2001.0985 · Cited by 253
Lateralization of olfactory processes
Royet, J.-P. (2004) · Chemical Senses · doi:10.1093/chemse/bjh067 · Cited by 220
Wansapura (1999) · doi:10.1002/(sici)1522-2586(199904)9:4
Metadata
- Authors
- Yang, Q. X., Dardzinski, B. J., Li, S., Eslinger, P. J., & Smith, M. B.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1997-03
- Volume
- 37
- Issue
- 3
- Pages
- 331-335
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2049005198
- Cited by
- 116
- References
- 1
- FWCI
- 8.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.