The DOI matches its Crossref record.
Limitations of temporal resolution in functional MRI
Abstract
In fMRI, images can be collected in a very short time; therefore, high temporal resolution is possible in principle. However, the temporal resolution is limited by a blurred intrinsic hemodynamic response and a finite signal‐to‐noise ratio. To determine the upper limit of temporal resolution in a single area during repeated tasks, motor cortex activity was investigated during visually instructed finger movements. Without averaging, a sequence of four single‐finger movements with an execution time of approximately 2 s can be resolved when the delay time between consecutive sequences is at least 3 s. The hemodynamic response time is constant for each subject, but not among different subjects. The temporal resolution can be better when the signal from spatially distinct regions is examined. For a series of experiments involving a visually instructed delayed cued finger movement task with a well‐defined, independently determined, variable delay time, time courses in the motor area are distinct from each other in two experiments if the difference in delay time is as little as 2 s. The activation in the visual area due to the presentation of the task serves here as an internal time reference. By comparing a set of fMRI time courses in multiple distinct areas, serial neural processing may be investigated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Konishi, S., Nakajima, K., Uchida, I., Kikyo, H., Kameyama, M., & Miyashita, Y. (1999) · Brain · doi:10.1093/brain/122.5.981 · Cited by 823
Optical magnetic detection of single-neuron action potentials using quantum defects in diamond
Barry, J. F., Turner, M. J., Schloss, J. M., Glenn, D. R., Song, Y., Lukin, M. D., Park, H., & Walsworth, R. L. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1601513113 · Cited by 637
Transient activation of inferior prefrontal cortex during cognitive set shifting
Konishi, S., Nakajima, K., Uchida, I., Kameyama, M., Nakahara, K., Sekihara, K., & Miyashita, Y. (1998) · Nature Neuroscience · doi:10.1038/283 · Cited by 401
Cunnington, R., Windischberger, C., Deecke, L., & Moser, E. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00291-x · Cited by 233
Cortical origins of response time variability during rapid discrimination of visual objects
Gerson, A. D., Parra, L. C., & Sajda, P. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.06.026 · Cited by 103
Metadata
- Authors
- Kim, S., Richter, W., & Uǧurbil, K.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1997-04
- Volume
- 37
- Issue
- 4
- Pages
- 631-636
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1975290352
- Cited by
- 287
- References
- 0
- FWCI
- 20.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Limitations of temporal resolution in functional MRI. https://app.cochat.ai/papers/10.1002/mrm.1910370427
- The paper
- Kim, S., Richter, W., & Uǧurbil, K. (1997). Limitations of temporal resolution in functional MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910370427
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.