Optical magnetic detection of single-neuron action potentials using quantum defects in diamond
Open accessAbstract
Significance: We demonstrate noninvasive detection of action potentials with single-neuron sensitivity, including in whole organisms. Our sensor is composed of quantum defects within a diamond chip, which detect time-varying magnetic fields generated by action potentials. The sensor is biocompatible and can be brought into close proximity to the organism without adverse effect, allowing for long-term observation and superior resolution of neuron magnetic fields. Optical magnetic detection with quantum defects also provides information about action potential propagation that is not easily available with existing methods. The quantum diamond technique requires no labeling or genetic modification, allows submillisecond time resolution, does not bleach, and senses through opaque tissue. With further development, we expect micrometer-scale magnetic imaging of a variety of neuronal phenomena.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Best reported diamond magnetometers' sensitivity is between 12 and 50 pT/Hz1/2, suitable for experimental recording of magnetic fields from isolated nerve or muscle tissues or invasive close-proximity high-resolution MCG of living rats, but not sufficient to compete with SQUIDs or OPMs for MCG clinical applications.
“Since the best reported diamond magnetometers’ sensitivity is between 12 and 50 pT/Hz1/2, they are suitable for experimental recording of magnetic fields from isolated nerve or muscle neuronal action potentials isolated nerve or muscle tissues (294) or even for invasive, close-proximity, high-resolution MCG of living rats (208), but do not have sufficient sensitivity to compete with SQUIDs or OPMs”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [294]
Cites
Neurophysiological investigation of the basis of the fMRI signal
Logothetis, N. K., Pauls, J., Augath, M., Trinath, T., & Oeltermann, A. (2001) · Nature · doi:10.1038/35084005 · Cited by 6,542 · see citing works
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893 · see citing works
Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655 · see citing works
Miniature cavity-enhanced diamond magnetometer
Chatzidrosos, G., Wickenbrock, A., Bougas, L., Leefer, N., Wu, T., Jensen, K., Dumeige, Y., & Budker, D. (2017) · Physical Review Applied · doi:10.1103/physrevapplied.8.044019 · Cited by 103 · see citing works
Millimetre-scale magnetocardiography of living rats with thoracotomy
Arai, K., Kuwahata, A., Nishitani, D., Fujisaki, I., Matsuki, R., Nishio, Y., Xin, Z., Cao, X., Hatano, Y., Onoda, S., et al. (2022) · Communications Physics · doi:10.1038/s42005-022-00978-0 · Cited by 85 · see citing works
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 71 · see citing works
Petrini, G., Moreva, E., Bernardi, E., Traina, P., Tomagra, G., Carabelli, V., Degiovanni, I. P., & Genovese, M. (2020) · Advanced Quantum Technologies · doi:10.1002/qute.202000066 · Cited by 63 · see citing works
Jensen, K., Budvytyte, R., Thomas, R. A., Wang, T., Fuchs, A. M., Balabas, M. V., Vasilakis, G., Mosgaard, L. D., Stærkind, H. C., Müller, J. H., et al. (2016) · Scientific Reports · doi:10.1038/srep29638 · Cited by 64 · see citing works
Magnetometry with nitrogen-vacancy centers in diamond
Jensen, K., Kehayias, P., & Budker, D. (2017) · Smart Sensors, Measurement and Instrumentation · doi:10.1007/978-3-319-34070-8_18 · Cited by 38 · see citing works
Optimizing NV magnetometry for magnetoneurography and magnetomyography applications
Zhang, C., Zhang, J., Widmann, M., Benke, M., Kübler, M., Dasari, D., Klotz, T., Gizzi, L., Röhrle, O., Brenner, P., et al. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.1034391 · Cited by 34 · see citing works
Development and Comprehensive Evaluation of TMR Sensor-Based Magnetrodes
Luo, J., Xu, Z., Jin, Z., Wang, M., Cai, X., & Chen, J. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c01148 · Cited by 21 · see citing works
Sorbo, A. R., Lombardi, G., La Brocca, L., Guida, G., Fenici, R., & Brisinda, D. (2018) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12526 · Cited by 18 · see citing works
Medical applications of diamond magnetometry: commercial viability
Dale, M. W., & Morley, G. W. (2017) · arXiv · doi:10.48550/arxiv.1705.01994 · Cited by 9 · see citing works
- Authors
- Barry, J. F., Turner, M. J., Schloss, J. M., Glenn, D. R., Song, Y., Lukin, M. D., Park, H., & Walsworth, R. L.
- Affiliations
- Harvard University (US)
- Boston Children's Hospital (US)
- Broad Institute (US)
- Corresponding author
- Walsworth, Ronald L.
- ORCID
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2016-11-22
- Volume
- 113
- Issue
- 49
- Pages
- 14133-14138
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC5150388
- OpenAlex
- W2266469747
- Cited by
- 637
- References
- 3
- Citations by year
- 2026: 63 · 2025: 79 · 2024: 68 · 2023: 81 · 2022: 62 · 2021: 82 · 2020: 55 · 2019: 57 · 2018: 58 · 2017: 28 · 2016: 4
- FWCI
- 21.83
- Type
- journal article
- Language
- en
- Update notices
- correction (2017-08-07)
- Open access
- bronze
- doi.org
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- Digital Access to Scholarship at Harvard (DASH) (Harvard University) (submittedVersion, cc-by)
- DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion, cc-by-nc)
- arXiv (Cornell University)
- Funders
- Defense Sciences Office, DARPA (HR0011-11-C-0073)
- NSF | MPS | Division of Physics (1504610)
- DOD | Army Research Office (W911NF-15-1-0548)
- National Science Foundation (1122374)
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Diamond and Carbon-based Materials Research
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Keywords
- neuronal action potentials, magnetic field sensing, nitrogen-vacancy centers, action potential conduction velocity, marine worms
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review