Cited by 637Diamond and Carbon-based Materials ResearchNeuroscience and Neural EngineeringAdvanced Fluorescence Microscopy Techniques

Optical magnetic detection of single-neuron action potentials using quantum defects in diamond

Open access
Barry, John F., Turner, Matthew J., Schloss, Jennifer M., Glenn, David R., Song, Yuyu, Lukin, Mikhail D., Park, Hongkun, Walsworth, Ronald L.·2016·Proceedings of the National Academy of Sciences

Abstract

Significance: We demonstrate noninvasive detection of action potentials with single-neuron sensitivity, including in whole organisms. Our sensor is composed of quantum defects within a diamond chip, which detect time-varying magnetic fields generated by action potentials. The sensor is biocompatible and can be brought into close proximity to the organism without adverse effect, allowing for long-term observation and superior resolution of neuron magnetic fields. Optical magnetic detection with quantum defects also provides information about action potential propagation that is not easily available with existing methods. The quantum diamond technique requires no labeling or genetic modification, allows submillisecond time resolution, does not bleach, and senses through opaque tissue. With further development, we expect micrometer-scale magnetic imaging of a variety of neuronal phenomena.

Integrity signals

Registry

Crossref · 10.1073/pnas.1601513113

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Best reported diamond magnetometers' sensitivity is between 12 and 50 pT/Hz1/2, suitable for experimental recording of magnetic fields from isolated nerve or muscle tissues or invasive close-proximity high-resolution MCG of living rats, but not sufficient to compete with SQUIDs or OPMs for MCG clinical applications.

    “Since the best reported diamond magnetometers’ sensitivity is between 12 and 50 pT/Hz1/2, they are suitable for experimental recording of magnetic fields from isolated nerve or muscle neuronal action potentials isolated nerve or muscle tissues (294) or even for invasive, close-proximity, high-resolution MCG of living rats (208), but do not have sufficient sensitivity to compete with SQUIDs or OPMs”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Barry, J. F., Turner, M. J., Schloss, J. M., Glenn, D. R., Song, Y., Lukin, M. D., Park, H., & Walsworth, R. L.
Affiliations
  • Harvard University (US)
  • Boston Children's Hospital (US)
  • Broad Institute (US)
Corresponding author
Walsworth, Ronald L.
Venue
Proceedings of the National Academy of Sciences
Published
2016-11-22
Volume
113
Issue
49
Pages
14133-14138
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W2266469747
Cited by
637
References
3
Citations by year
2026: 63 · 2025: 79 · 2024: 68 · 2023: 81 · 2022: 62 · 2021: 82 · 2020: 55 · 2019: 57 · 2018: 58 · 2017: 28 · 2016: 4
FWCI
21.83
Type
journal article
Language
en
Open access
Locations
  • Proceedings of the National Academy of Sciences (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • Digital Access to Scholarship at Harvard (DASH) (Harvard University) (submittedVersion, cc-by)
  • DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion, cc-by-nc)
  • arXiv (Cornell University)
Funders
  • Defense Sciences Office, DARPA (HR0011-11-C-0073)
  • NSF | MPS | Division of Physics (1504610)
  • DOD | Army Research Office (W911NF-15-1-0548)
  • National Science Foundation (1122374)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Diamond and Carbon-based Materials Research
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
Keywords
neuronal action potentials, magnetic field sensing, nitrogen-vacancy centers, action potential conduction velocity, marine worms

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review