A new method for absolute quantitation MRS metabolites
Open accessThe DOI matches its Crossref record.
Abstract
A new method for absolute of MRS spectra is presented. This method is not based on a reference peak, derived from a real NMR signal, but rather on a synthesized NMR reference produced by an electronic device, transmitted by a broad‐band antenna to avoid quality factor variations. This signal is therefore received at the same time as the sample signal. The reference line produced is stable in time (maximum variation lower than 2%) and allows precise and accurate measurement of absolute concentrations (mean error lower than 3%) in vitro and in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Concentration Measurement by Proton NMR Using the ERETIC Method
Akoka, S., Barantin, L., & Trierweiler, M. (1999) · Analytical Chemistry · doi:10.1021/ac981422i · Cited by 519
Self-citationMeasuring Protein Concentrations by NMR Spectroscopy
Wider, G., & Dreier, L. (2006) · Journal of the American Chemical Society · doi:10.1021/ja055336t · Cited by 461
Quantitative NMR spectroscopy in pharmaceutical applications
Holzgrabe, U. (2010) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2010.05.001 · Cited by 362
Near, J., Harris, A. D., Juchem, C., Kreis, R., Marjańska, M., Öz, G., Slotboom, J., Wilson, M., & Gasparovic, C. (2021) · NMR in Biomedicine · doi:10.1002/nbm.4257 · Cited by 342
NMR Techniques for Noble Metal Nanoparticles
Marbella, L. E., & Millstone, J. E. (2015) · Chemistry of Materials · doi:10.1021/cm504809c · Cited by 289
Quantitative analysis of prostate metabolites using 1H HR‐MAS spectroscopy
Swanson, M. G., Zektzer, A. S., Tabatabai, Z. L., Simko, J., Jarso, S., Keshari, K. R., Schmitt, L., Carroll, P. R., Shinohara, K., Vigneron, D. B., et al. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20909 · Cited by 249
“, Electronic REference To access In vivo Concentrations (ERETIC) (16) have been investigated.”
BackgroundCell culture metabolomics: applications and future directions
Čuperlović-Culf, M., Barnett, D. A., Culf, A. S., & Chute, I. (2010) · Drug Discovery Today · doi:10.1016/j.drudis.2010.06.012 · Cited by 228
Diurnal rhythms in the human urine metabolome during sleep and total sleep deprivation
Giskeødegård, G. F., Davies, S. K., Revell, V. L., Keun, H., & Skene, D. J. (2015) · Scientific Reports · doi:10.1038/srep14843 · Cited by 135
Sitter, B., Bathen, T. F., Tessem, M.-B., & Gribbestad, I. S. (2009) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2008.10.001 · Cited by 91
HR-MAS NMR Based Quantitative Metabolomics in Breast Cancer
Gogiashvili, M., Nowacki, J., Hergenröder, R., Hengstler, J. G., Lambert, J., & Edlund, K. (2019) · Metabolites · doi:10.3390/metabo9020019 · Cited by 44
“A widely used method to quantify metabolites in tissue is ERETIC (Electronic REference To access In vivo Concentrations), an artificially generated radio frequency signal, which is pre-calibrated to a reference sample, such as sucrose, in an independent measurement [81,82].”
Method
Metadata
- Authors
- Barantin, L., Pape, A. L., & Akoka, S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1997-08
- Volume
- 38
- Issue
- 2
- Pages
- 179-182
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2006710432
- Cited by
- 156
- References
- 0
- FWCI
- 1.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.